WIRING TYPE, ACTION, STATE, RESPONSE, Button Station and 1
View all LiftMaster JDC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 40 highlights
Programming (continued) WIRING TYPE T (continued) DEVICE ACTION STATE RESPONSE Operator at OPEN limit Door closes to the CLOSE limit Operator at CLOSE limit Door opens to the OPEN limit or Mid-Stop Door opening Door stops Single Button Wall Button is pressed Controller (Wired) Door closing Door will auto reverse to OPEN limit or Mid-Stop and activates TTC Door at Open Mid-Stop Door opens to the OPEN limit and activates TTC Door stopped during the open cycle Door closes to the CLOSE limit Door stopped during the close cycle Door opens to the OPEN limit or Mid-Stop and activates TTC Button is held (constant Door opening pressure) No change in state Operator at OPEN limit No change in state (Recycle timer) Operator at CLOSE limit Door opens to the OPEN limit or Mid-Stop and activates TTC Open is pressed Door opening Door closing No change in state Door will auto reverse to OPEN limit or Mid-Stop and activates TTC myQ® Smart Facility Access Door at Open Mid-Stop Door stopped during open or close cycle Operator at OPEN limit Door opens to the OPEN limit and activates TTC Door opens to the OPEN limit or Mid-Stop and activates TTC Door closes to the CLOSE limit Operator at CLOSE limit No change in state Close is pressed Door opening Door closing Door at Open Mid-Stop No change in state No change in state Door closes to the CLOSE limit Door stopped during open or close cycle Door closes to the CLOSE limit WIRING TYPE DEVICE ACTION STATE RESPONSE TS This mode will attempt to close the door from any position except when fully closed, or when a safety input is present. The stop button will recycle the Timer-To-Close (TTC) at any position. To disable the TTC in this mode, installation of a defeat switch is required (see wiring diagram). Operator at OPEN limit No change in state (Recycle TTC) Operator at CLOSE limit Door opens to the OPEN limit or Mid-Stop and activates TTC OPEN Door opening No change in state button is pressed Door closing momentarily Door at Open Mid-Stop Door will auto reverse to OPEN limit or MidStop and activates TTC Door opens to the OPEN limit and activates TTC Door stopped during open or close cycle Door opens to the OPEN limit or Mid-Stop and activates TTC Operator at OPEN limit Door closes to the CLOSE limit CLOSE Operator at CLOSE limit No change in state button is Door opening No change in state Momentary contact to open, close, and stop with open override and TTC. Every device that causes door to open, including a reversing device, activates the TTC. Auxiliary controls can be connected to open input to activate the TTC. If the timer has been activated, the open button and radio control can recycle the timer. The TTC will function from the Open limit and Open mid stop with this operating mode type. Close Mid Stop available but not shown in table. Compatible with 3-Button Station, 1-Button Station and 1 and 3-Button Remote Control. Monitored Entrapment Protection (LMEP) Device required. pressed Door closing momentarily Door at Open Mid-Stop No change in state Door closes to the CLOSE limit Door stopped during open or close cycle Door closes to the CLOSE limit Operator at OPEN limit No change in state (Recycle TTC) Front panel STOP Operator at CLOSE limit No change in state buttons button is Door opening Door stops and activates TTC (membrane) pressed Door closing Door stops and activates TTC and 3-Button momentarily Door at Open Mid-Stop No change in state (Recycle TTC) Wall Door stopped during open or close cycle No change in state (Recycle TTC) Controller Operator at OPEN limit No change in state (Recycle & hold TTC) Operator at CLOSE limit Door opens to the OPEN limit (bypasses Mid-Stop) and activates TTC OPEN button Door opening No change in state (bypasses Mid-Stop) and activates TTC is held (constant pressure) Door closing Door at Open Mid-Stop Door will auto reverse to OPEN limit (bypasses Mid-Stop) and activates TTC Door opens to the OPEN limit and activates TTC Door stopped during open or close cycle Door opens to the OPEN limit (bypasses Mid-Stop) and activates TTC Operator at OPEN limit Door closes to the CLOSE limit CLOSE button is held (constant Operator at CLOSE limit Door opening Door closing Door at Open Mid-Stop No change in state No change in state No change in state Door closes to the CLOSE limit pressure) Door stopped during open or close cycle Door closes to the CLOSE limit 40