Chapter 4 Configure/View SCSI Controller Settings There are 8 items in the "Configure/View SCSI Controller Settings" screen. These items display or allow you to change the SCSI controller's settings. Use the arrow keys to highlight the item and then press to select the value you want in each item or enter each item's sub-menu screen. AIC-7899 A at slot 0D, 03:07:00 Options SCSI Bus Interface Definitions SCSI Controller ID 7 SCSI Controller Parity Enabled SCSI Controller Termination Enabled Additional Options Boot Device Configuration Press SCSI Device Configuration Press Advanced Configuration Press -- Reset to SCSI Controller Defaults BIOS Information Interrupt (IRQ) Channel 1 1 I/O Port Address B000h SCSI Bus Interface Definitions SCSI Controller ID The item is used to assign a SCSI ID to the SCSI controller. It is recommended that you should leave the default setting unchanged. Settings: 0~15. SCSI Controller Parity Use the field to enable or disable SCSI parity error checking function. If any of your SCSI devices does not support parity checking, disable this function. While disabling the function, you should disable disconnections for all devices, as parity checking for the reselection phase is NOT disabled. A non-parity device's I/O operation will never complete if the reselection fails due to a parity 4-4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79

Chapter 4
4-4
Configure/View SCSI Controller Settings
SCSI Bus Interface Definitions
SCSI Controller ID
The item is used to assign a SCSI ID to the SCSI controller.
It is recommended
that you should leave the default setting unchanged.
Settings:
0~15
.
SCSI Controller Parity
Use the field to enable or disable SCSI parity error checking function.
If any of
your SCSI devices does not support parity checking, disable this function.
While disabling the function, you should disable disconnections for all devices,
as parity checking for the reselection phase is NOT disabled.
A non-parity
device’s I/O operation will never complete if the reselection fails due to a parity
There are 8 items in the “Configure/View SCSI Controller Settings” screen.
These items display or allow you to change the
SCSI controller’s settings.
Use
the arrow keys to highlight the item and then press <Enter> to select the value
you want in each item or enter each item’s sub-menu screen.
AIC-7899 A at slot 0D, 03:07:00
SCSI Bus Interface Definitions
SCSI Controller ID
..................................
7
SCSI Controller Parity
............................
Enabled
SCSI Controller Termination
.................
Enabled
Additional Options
Boot Device Configuration
....................
Press <Enter>
SCSI Device Configuration
.....................
Press <Enter>
Advanced Configuration
.........................
Press <Enter>
<F6> -- Reset to SCSI Controller Defaults
Options
Interrupt (IRQ) Channel
........................
11
I/O Port Address
......................................
B000h
BIOS Information