MSI E7500 User Manual - Page 72

Sync Transfer Rate MB/Sec, Initiate Wide Negotiation, Enable Disconnection, Send Start Unit Command

Page 72 highlights

Chapter 4 SCSI Device ID SCSI Device Configuration #0 #1 #2 #3 #4 #5 #6 #7 Sync Transfer Rate (MB/Sec) ...... 160 160 160 160 160 160 160 160 Initiate Wide Negotiation Yes Yes Yes Yes Yes Yes Yes Yes Enable Disconnection Yes Yes Yes Yes Yes Yes Yes Yes Send Start Unit Command .......... Yes Yes Yes Yes Yes Yes Yes Yes Options Listed Below Has NO EFFECT if Int 13 Support is Disabled BIOS Multiple LUN Support ...... No No No No No No No No Include in BIOS Scan Yes Yes Yes Yes Yes Yes Yes Yes SCSI Device ID #8 #9 #10 #11 #12 #13 #14 #15 Sync Transfer Rate (MB/Sec) ...... 160 160 160 160 160 160 160 160 Initiate Wide Negotiation Yes Yes Yes Yes Yes Yes Yes Yes Enable Disconnection Yes Yes Yes Yes Yes Yes Yes Yes Send Start Unit Command .......... Yes Yes Yes Yes Yes Yes Yes Yes Options Listed Below Has NO EFFECT if Int 13 Support is Disabled BIOS Multiple LUN Support ...... No No No No No No No No Include in BIOS Scan Yes Yes Yes Yes Yes Yes Yes Yes Sync Transfer Rate (MB/Sec) The field allows you to specify the maximum synchronous data transfer rate depending on the type of each SCSI device. Select ASYN to enable asynchronous negotiation for some older SCSI devices. Initiate Wide Negotiation When set to Yes, the field allows wide SCSI hard drives to use 16-bit (2 bytes) transfers. Enable Disconnection This field tells the SCSI controller whether or not to allow the specified SCSI device to disconnect during an I/O transfer operation. The disconnection ability frees the SCSI bus to allow other I/O processes and thus optimizes the SCSI bus performance. Setting options: Yes, No. Send Start Unit Command When set to Yes, the SCSI controller sends the Start Unit command to the specified SCSI device during bootup. The interface powers up the SCSI device on-at-a-time during bootup, reducing the load on the computer's 4-6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79

Chapter 4
4-6
Sync Transfer Rate (MB/Sec)
The field allows you to specify the maximum synchronous data transfer
rate depending on the type of each SCSI device.
Select
ASYN
to enable
asynchronous negotiation for some older SCSI devices.
Initiate Wide Negotiation
When set to
Yes
, the field allows wide SCSI hard drives to use 16-bit (2
bytes) transfers.
Enable Disconnection
This field tells the SCSI controller whether or not to allow the specified
SCSI device to disconnect during an I/O transfer operation.
The discon-
nection ability frees the SCSI bus to allow other I/O processes and thus
optimizes the SCSI bus performance. Setting options:
Yes, No
.
Send Start Unit Command
When set to
Yes
, the SCSI controller sends the Start Unit command to the
specified SCSI device during bootup.
The interface powers up the SCSI
device on-at-a-time during bootup, reducing the load on the computer’s
SCSI Device ID
#0
#1
#2
#3
#4
#5
#6
#7
Sync Transfer Rate (MB/Sec)
......
160
160
160
160
160
160
160
160
Initiate Wide Negotiation
.............
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Enable Disconnection
.....................
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Send Start Unit Command
..........
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
BIOS Multiple LUN Support
......
No
No
No
No
No
No
No
No
Include in BIOS Scan
.....................
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
SCSI Device ID
#8
#9
#10
#11
#12
#13
#14
#15
Sync Transfer Rate (MB/Sec)
......
160
160
160
160
160
160
160
160
Initiate Wide Negotiation
.............
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Enable Disconnection
.....................
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Send Start Unit Command
..........
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
BIOS Multiple LUN Support
......
No
No
No
No
No
No
No
No
Include in BIOS Scan
.....................
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
SCSI Device Configuration
Options Listed Below Has NO EFFECT if Int 13 Support is Disabled
Options Listed Below Has NO EFFECT if Int 13 Support is Disabled