Meade 12 inch Instruction Manual - Page 6
Caution: All LX200 Owners - ball drop
View all Meade 12 inch manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
-6- celestial software library; 25 ft. power cord and adapter for As the high intensity light passes through the Schmidt corrector telescope operation from 115v.AC; 8 x 50mm viewfinder; plate, most of it is transmitted through (about 98%+) while the eyepiece-holder and diagonal prism (1.25"); Series 4000 rest of the light scatters through the glass. As the light hits the SP26mm eyepiece; variable-height field tripod; operating mirrored surfaces, most of it is reflected back (about 94%) while instructions. the rest of it scatters across the coatings. The total amount of d. 12" Model LX200 lncludes 12" Schmidt-Cassegrain optical tube assembly with EMC super multi-coatings (D = 305mm, F = 3048mm-f/10); heavy-duty fork mount, with 4"-dia. sealed polar ball bearing, quartz-microprocessor-controlled 5.75" worm gears on both scattered light will be significant, and its effects allow you to see microscopic details that are normally invisible to the unaided eye. These anomalous details are real, but their combined effects will in no way impose limits on the optical performance, even under the most demanding observing or imaging criteria. axes, and multi-function power panel display on the drive base; 4. Caution: All LX200 Owners manual and electric slow-motion controls on both axes; setting circles in RA and Dec; handheld keypad Electronic Command Center with digital readout display, PPEC Smart Drive, 7-speed drive control on both axes, GO TO controller, High-Precision Pointing, and 64,340-object onboard celestial software library; 25 ft. power cord and adapter for telescope operation from 115v.AC; 8 x 50mm viewfinder; 2" diagonal mirror with 1.25" adapter; Series 4000 SP26mm eyepiece; giant field tripod; foam-fitted carrying case; operating instructions. CAUTION: Serious damage to the drive gears may result from shock in handling, while transporting or commercially shipping the LX200, should the R.A. lock (7, Fig. 1), and/or the Dec. lock (2, Fig. 4) be left engaged. Always release the locks when storing in the case, or when crating for commercial shipment to allow the telescope to give, if the case or crate is sharply jarred or dropped. Also, the optical and mechanical axes of all LX200 UNPACKING AND INSPECTION telescopes have been carefully aligned at the factory As you begin to unpack your telescope from its cartons, you will to ensure accurate object pointing. Do not loosen or probably be interested in setting it up right away; we certainly remove the fork arms or optical tube assembly from understand your excitement but please take a few minutes to the drive base; the resulting misalignment of the axes read this page before doing so. You should verify that you have will result in inaccurate slewing of the telescope in the all the proper equipment, and that it has arrived to you GO TO mode. undamaged. We strongly recommend that you keep your original packing materials. If it should ever become necessary for you to return 5. Caution: 10" and 12" LX200 Owners CAUTION: Do not attempt to turn the focuser knob of your telescope to the Meade factory for servicing, these will the optical tube until you have read this note! help ensure that no shipping damage will occur. Meade LX200 telescopes supplied to countries outside the U.S.A. are identical to those offered domestically, with the exception of the AC wall adapter. NOTE: Next to the base of the focuser you will see a redcolored slotted head bolt. This bolt is used only for safety in shipment. Remove this bolt before attempting to turn the focuser knob. In its place, insert the rubber plug provided as a 1. What You Should Have Carefully unpack and remove all the telescope parts from their dust protector (this rubber plug is included with your hardware package). packing material. Compare each part to the Standard Your focuser is now operational. Equipment. You may wish to place a check next to each item as you identify it. These Packing Programs represent the original specifications for this instrument. Each telescope has been inspected twice at the factory to confirm the inclusion of every item. 2. Please Look Everything Over WARNING: The 10" and 12" LX200 should never be commercially shipped without this red-colored bolt in place. This is essential during commercial transport where rough handling may occur. For your personal transport and storage, you will never have to use this bolt again. Meade Instruments and your shipper have taken precautions to ensure that no shipping damage will occur, but if your shipment a. Commercial Reshipment has suffered severe vibration or impact damage (whether or not To commercially re-ship the telescope, be sure to follow this the shipping cartons show damage) then it is important that you procedure: retain all the original packing and contact the shipper to arrange a formal inspection of the package or packages. This procedure is required prior to any warranty servicing by Meade Instruments. 3. Inspecting the Optics 1. Turn the focuser knob clockwise until it stops. This will bring the primary mirror all the way back in the tube. 2. Remove the rubber plug and insert the red-headed bolt. Thread it in to a firm snug feel. Do not overtighten. (If you have misplaced the red-headed bolt, you may use any Note on the "Flashlight" Test: If a flashlight or other high- other bolt that is 1/4-20x1" long. intensity light source is pointed down the main telescope tube, you may at first be shocked at the appearance of the optics. To the uninitiated, the view (depending on your line of sight and the angle the light is coming from) may reveal what would appear to be scratches, dark or bright spots, or just generally uneven coatings, giving the appearance of poor surface quality. These effects are only seen when a high intensity light is transmitted through lenses or reflected off the mirrors, and can be seen on any high quality optical system, including the giant research telescopes in use today. It should be pointed out, 3. When packaging the 10" or 12" LX200, be sure to release the R.A. lock (7, Fig. 1), and Dec. lock (2, Fig. 4), to prevent shock to the gears in the motor assemblies should the package suffer severe handling. Please note that commercial shipment of the 10" and 12" LX200 Telescope without the safety bolt in place and packed in the original factory supplied shipping containers as described above is done at the owner's risk and your warranty may be voided if shipping damage results. however, that optical quality cannot be judged by this grossly misleading "test", but through careful star testing. The Flashlight Test causes even the very best optics to look "terrible". 6. Keypad Version Number The current keypad version is 3.20 (see sticker on back of keypad). This does not indicate the telescope software version-which is displayed on the keypad LED at power-up.