NEC LT80 User Manual - Page 45
Cable Connection, Communication Protocol
View all NEC LT80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
87 Cable Connection Communication Protocol Baud rate: 9600 bps Data length: 8 bits Parity: No parity Stop bit: One bit X on/off: Communications procedure: None Full duplex If the CPU of the projector has received the data correctly, it returns an ACK(C5H). If the received data is not correct, the CPU returns a NAK(CAH), then the following status: Receiving success: C5 Receiving failure: CA Err Err 01: Command Error (command not supported) Err 02: Checksum Error Err 03: Busy (command not acceptable) Err 04: Parameter Error ( parameter data abnormal) PC Control Connector (DIN-8P) NOTE: If failing in powering-on, the CPU returns the following NAKs: CA Err 1 Err 1 8X (Apply the corresponding bit.) Bit 0: Lamp housing is not attached correctly Bit 1: Fan stoppage Bit 2: Overheated Bit 3: Lamp lighting failure 87 5 4 2 6 3 1 To GND of PC ᮤ To RxD of PC ᮣ 44 To TxD of PC ᮣ SPECIFICATIONS 88