Netgear GSM7224 GSM7224 User Manual - Page 97
set garp timer leaveall, Default, Format - 200
UPC - 606449069150
View all Netgear GSM7224 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 97 highlights
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Mode Global Config set garp timer leaveall This command sets how frequently Leave All PDUs are generated per port. A Leave All PDU indicates that all registrations will be unregistered. Participants would need to rejoin in order to maintain registration. The value applies per port and per GARP participation. The time may range from 200 to 6000 (centiseconds). Note: This command has an effect only when GVRP is enabled. Default 1000 centiseconds (10 seconds) Format set garp timer leaveall Mode Interface Config no set garp timer leaveall This command sets how frequently Leave All PDUs are generated per port to 1000 centiseconds (10 seconds). Note: This command has an effect only when GVRP is enabled. Format no set garp timer leaveall Mode Interface Config set garp timer leaveall all This command sets how frequently Leave All PDUs are generated for all ports. A Leave All PDU indicates that all registrations will be unregistered. Participants would need to rejoin in order to maintain registration. The value applies per port and per GARP participation. The time may range from 200 to 6000 (centiseconds). Note: This command has an effect only when GVRP is enabled. Default 1000 centiseconds (10 seconds) Format Mode set garp timer leaveall all Global Config Switching Commands 202-10009-01_060204 8-45