Netgear XSM7224S XSM7224S Hardware Installation Guide - Page 6

Left side LED, Table 1., LED Descriptions for XSM7224S - 10g switch

Page 6 highlights

Managed Stackable Switch XSM7224S l Table 1. LED Descriptions for XSM7224S LED ID Stack Master Power Fan 10GBT Ports (2 LEDs per port) Description This is the stack member ID (1-99) that the software assigns to the switch. • Green: The switch acts as a master unit in a stack of XSM7224S series switches. • Off: The switch acts as a slave unit in a stack of XSM7224S series switches. • Solid green: The power module is present, is supplying power to the switch, and is working normally. • Solid yellow: The system is in boot-up stage. • Blinking yellow: Power module is present but has failed. • Off: Power is disconnected. • Solid green: The fan is operating normally. • Solid yellow: The fan has failed. • Off: No fan is detected. Right side LED 10/100M Link/ACT LED: • Off: No 10/100M link is established on the port. • Solid yellow: A valid 10/100M link is established on the port. • Blinking yellow: The port is transmitting or receiving packets at 10/100Mbps. SFP+ Ports (1 SPD/Link/ACT LED per port) Left side LED 1G/10G Link/ACT LED: • Off: No 1G/10G link is established on the port. • Solid Green - A valid 10Gbps link is established on the port. • Blinking Green - Packet transmission or reception is occurring on the port at 10Gbps. • Solid Yellow - A valid 1000Mbps link is established on the port. • Blinking Yellow - Packet transmission or reception is occurring on the port at 1000Mbps. Note: If port 21-24 media is changed to SFP+, the RJ-45 LEDs change to OFF status. • Off: No SFP/SFP+ module link is established on the port. • Solid green: A valid 10Gbps SFP+ module link is established on the port. • Blinking green: The port is transmitting or receiving packets at 10Gbps. • Solid yellow: A valid 1Gbps SFP module link is established on the port. • Blinking yellow: Packet transmission or reception is occurring on the port at 1Gbps. Note: If port 21-24 media is changed to copper, the SFP+ LEDs change to Off status. 6 | Chapter 1. Introduction

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

6
|
Chapter 1.
Introduction
Managed Stackable Switch XSM7224S
l
Table 1.
LED Descriptions for XSM7224S
LED
Description
ID
This is the stack member ID (1–99) that the software assigns to the switch.
Stack Master
Green
: The switch acts as a master unit in a stack of XSM7224S series
switches.
Off
: The switch acts as a slave unit in a stack of XSM7224S series switches.
Power
Solid green
: The power module is present, is supplying power to the switch, and
is working normally.
Solid yellow
: The system is in boot-up stage.
Blinking yellow
: Power module is present but has failed.
Off
: Power is disconnected.
Fan
Solid green
: The fan is operating normally.
Solid yellow
: The fan has failed.
Off
: No fan is detected.
10GBT Ports
(2 LEDs per port)
10/100M Link/ACT LED:
Off
: No 10/100M link is established on the port.
Solid yellow
: A valid 10/100M link is established on the port.
Blinking yellow
: The port is transmitting or receiving packets
at
10/100Mbps.
Left side LED
1G/10G Link/ACT LED:
Off
: No 1G/10G link is established on the port.
Solid Green –
A valid 10Gbps link is established on the port.
Blinking Green –
Packet transmission or reception is occurring on the port at
10Gbps.
Solid Yellow
– A valid 1000Mbps link is established on the port.
Blinking Yellow
– Packet transmission or reception is occurring on the port at
1000Mbps.
Note:
If port 21–24 media is changed to SFP+, the RJ-45 LEDs change to OFF
status.
SFP+ Ports
(
1 SPD/Link/ACT
LED per port)
Off
: No SFP/SFP+ module link is established on the port.
Solid green
: A valid 10Gbps SFP+ module link is established on the port.
Blinking green
: The port is transmitting or receiving packets at 10Gbps.
Solid yellow
: A valid 1Gbps SFP module link is established on the port.
Blinking yellow
: Packet transmission or reception is occurring on the port at
1Gbps.
Note:
If port 21–24 media is changed to copper, the SFP+ LEDs change to Off
status.
Right side LED