Onkyo HT-R570 Owner Manual - Page 40

Using Audyssey 2EQ™, Listening Position - speaker setup microphone

Page 40 highlights

First Time Setup-Continued Using Audyssey 2EQ™ Notes: • If the AV receiver is muted, it will be unmuted automatically when the Audyssey 2EQ Room Correction and Speaker Setup starts. • Room correction and speaker setup cannot be performed while a pair of headphones is connected. • It takes about 10 minutes to complete the room correction and speaker setup for three positions. Total measurement time varies depending on the number of speakers. • Do not connect or disconnect any speakers during room correction and speaker setup. ON/STANDBY Speaker setup microphone SETUP MIC Notes: • Before starting Audyssey 2EQ Room Correction and Speaker Setup, arrange the room and connect the speakers as you would for enjoying movies. Changes to the room after auto setup requires you run the auto setup again, as room EQ characteristics may have changed. • When starting the room correction and speaker setup, do not stand between the speakers and microphone, and avoid obstacles blocking the path between speakers and microphone. This will produce inaccurate results. • Position the microphone at ear height of a seated listener with the microphone tip pointed directly at the ceiling using a tripod. Do not hold the microphone in your hand during measurements as this will produce innacurate results. • Make the room as quiet as possible. Background noise can disrupt the room measurements. Close windows, silence cell phones, televisions, radios, air conditioners, fluorescent lights, home appliances, light dimmers, or other devices. • Cell phones should be turned off or placed away from all audio electronics during the measurement process as Radio Frequency Interference (RFI) may cause measurement disruptions (even if the cell phone is not in use). 3 Press [ENTER]. The room calibration and speaker setup starts. 1 2 40 ENTER Turn on the AV receiver. Set the speaker setup microphone at the Main Listening Position B (page 39), and connect it to the SETUP MIC jack. Audyssey indicator Test tones are played through each speaker as Audyssey 2EQ Room Correction and Speaker Setup runs. This process takes a few minutes. Please refrain from talking during measurements and do not stand between speakers and the microphone. Note: You can cancel the Room Correction and Speaker Setup at any point in this procedure simply by disconnecting the setup microphone. 4 When the following display appears, move the speaker setup microphone to measurement point C (page 39), and then press [ENTER]. Audyssey 2EQ performs more measurements. This takes a few minutes.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

40
First Time Setup
—Continued
Using Audyssey 2EQ™
Notes:
Before starting Audyssey 2EQ Room Correction and
Speaker Setup, arrange the room and connect the
speakers as you would for enjoying movies. Changes
to the room after auto setup requires you run the auto
setup again, as room EQ characteristics may have
changed.
When starting the room correction and speaker setup,
do not stand between the speakers and microphone,
and avoid obstacles blocking the path between
speakers and microphone. This will produce
inaccurate results.
Position the microphone at ear height of a seated
listener with the microphone tip pointed directly at the
ceiling using a tripod. Do not hold the microphone in
your hand during measurements as this will produce
innacurate results.
Make the room as quiet as possible. Background noise
can disrupt the room measurements. Close windows,
silence cell phones, televisions, radios, air
conditioners, fluorescent lights, home appliances,
light dimmers, or other devices.
Cell phones should be turned off or placed away from
all audio electronics during the measurement process
as Radio Frequency Interference (RFI) may cause
measurement disruptions (even if the cell phone is not
in use).
1
Turn on the AV receiver.
2
Set the speaker setup
microphone at the Main
Listening Position
a
(page 39),
and connect it to the SETUP MIC
jack.
Notes:
If the AV receiver is muted, it will be unmuted
automatically when the Audyssey 2EQ Room
Correction and Speaker Setup starts.
Room correction and speaker setup cannot be
performed while a pair of headphones is
connected.
It takes about 10 minutes to complete the room
correction and speaker setup for three positions.
Total measurement time varies depending on the
number of speakers.
Do not connect or disconnect any speakers during
room correction and speaker setup.
ENTER
ON/STANDBY
SETUP MIC
Speaker setup microphone
Audyssey indicator
3
Press [ENTER].
The room calibration and speaker setup starts.
Test tones are played through each speaker as
Audyssey 2EQ Room Correction and Speaker
Setup runs. This process takes a few minutes.
Please refrain from talking during measure-
ments and do not stand between speakers and
the microphone.
Note:
You can cancel the Room Correction and
Speaker Setup at any point in this procedure
simply by disconnecting the setup microphone.
4
When the following display appears,
move the speaker setup microphone to
measurement point
b
(page 39), and
then press [ENTER].
Audyssey 2EQ performs more measurements.
This takes a few minutes.