■ Connections You can connect up to seven extension units with the digital disk recorder (the WJ-HD300 series) as shown below using the supplied serial cables. Important • If turning off the power of a unit, none of the connected following units will work because of interrupted data transmission. • Never use extension cables (locally procured). Be sure to use the supplied serial cables for connection. Do not lay cables in a redundant route. Otherwise, it may cause data transmission error. • Make a space of 1 U (44 mm) between the units in a rack for ventilation. • Follow the recommended connection form. Otherwise, it may cause malfunction of the system. • Physical connections determine the unit number in a system for each unit. Connect units with the recorder in numeric order as shown in the figure. For example, connect the sixth and seventh units to the third unit when five units have been already installed. • Do not change connections after the system has run. Otherwise, the recorder will no longer recognize the extension units as before. You can change connections only when you can discard all existing data stored in the units. ● Recommended Connection Form Layer1 Layer2 Layer3 Layer4 WJ-HD300 Series EXT STORAGE IN WJ-HDE300 #1 OUT2 OUT1 IN WJ-HDE300 #2 OUT2 OUT1 IN WJ-HDE300 #4 IN WJ-HDE300 #5 IN WJ-HDE300 #3 OUT2 OUT1 IN WJ-HDE300 #6 IN WJ-HDE300 #7 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

14
Connections
You can connect up to seven extension units with the digital
disk recorder (the WJ-HD300 series) as shown below using
the supplied serial cables.
Important
If turning off the power of a unit, none of the con-
nected following units will work because of inter-
rupted data transmission.
Never use extension cables (locally procured). Be
sure to use the supplied serial cables for connec-
tion. Do not lay cables in a redundant route.
Otherwise, it may cause data transmission error.
Make a space of 1 U (44 mm) between the units in
a rack for ventilation.
Follow
the
recommended
connection
form.
Otherwise, it may cause malfunction of the system.
Physical connections determine the unit number in
a system for each unit. Connect units with the
recorder in numeric order as shown in the figure.
For example, connect the sixth and seventh units to
the third unit when five units have been already
installed.
Do not change connections after the system has
run. Otherwise, the recorder will no longer recog-
nize the extension units as before. You can change
connections only when you can discard all existing
data stored in the units.
Recommended Connection Form
WJ-HD300 Series
WJ-HDE300 #1
WJ-HDE300 #2
WJ-HDE300 #4
WJ-HDE300 #3
WJ-HDE300 #5
WJ-HDE300 #7
WJ-HDE300 #6
Layer1
Layer2
Layer3
Layer4
EXT STORAGE
IN
IN
IN
IN
IN
IN
IN
OUT1
OUT2
OUT1
OUT2
OUT1
OUT2