Sharp A260 Service Manual - Page 11

Soft switch description

Page 11 highlights

UX-A260U 5. Soft switch description • Soft switch SW DATA NO. NO. ITEM Switch setting and function 1 0 Initial setting 1 Protect from echo No Yes 0 2 Forced 4800 BPS reception Yes No 0 3 Footer print Yes No 0 4 Length limitation of copy/send/receive No limit Copy/send: 60cm 0 SW Receive: 1m l 5 CSI transmission No transmitted Transmitted 0 A1 6 DIS receive acknowledgement during G3 Twice NSF: Once 0 transmission DIS: Twice 7 Non-modulated carrier for V29 transmission Yes No 0 mode 8 EOL detect timer 25 s 13 s 0 Modem speed V.33 V.17 V.29 V.27 ter 14400 12000 14400 12000 9600 7200 9600 7200 4800 2400 1 2 SW 3 l 4 A2 5 Sender's information transmit 0011110000 1 1100000000 0 0101010110 0 0000111100 0 No Yes 0 6 Reserved 0 7 Communication error treatment in RTN No communication error Communication error 0 sending mode (reception) 8 CNG transmission CED tone signal interval 1 No Yes 0 1000ms 750ms 500ms 75ms No. 1 1 1 0 0 0 2 No. 2 1 0 1 0 0 SW 3 MR coding No Yes 0 l 4 ECM mode No Yes 0 A3 5 ECM MMR mode No Yes 0 6 Reserved 0 7 Reserved 0 8 Reserved 0 1 Signal transmission level Binary input 0 2 No. = 16 8 4 2 1 1 3 SW l 4 A4 5 1 2345 0 0 1000 0 0 6 Protocol monitor (error print) Printed at com. error Not printed 0 7 Protocol monitor Yes No 0 8 Line monitor Yes No 0 Digital line equalization setting (Reception) 7.2km 3.6km 1.8km 0km 1 No. 1 1 1 0 0 0 2 No. 2 1 0 1 0 1 Digital line equalization setting 7.2km 3.6km 1.8km 0km SW 3 (Transmission) l 4 A5 Digital cable equalizer setting (Reception No. 3 No. 4 1 1 1 0 7.2km 0 0 0 1 0 1 0km 5 for Caller ID) 6 No. 5 1 No. 6 1 0 0 0 0 7 Error criterion 10 ~ 20 % 5 ~ 10 % 0 8 Anti junk fax check Yes No 1 Remarks OPTION 2 - 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76

UX-A260U
5. Soft switch description
• Soft switch
2 – 5
1
Protect from echo
No
Yes
0
2
Forced 4800 BPS reception
Yes
No
0
3
Footer print
Yes
No
0
4
Length limitation of copy/send/receive
No limit
Copy/send: 60cm
0
Receive: 1m
5
CSI transmission
No transmitted
Transmitted
0
6
DIS receive acknowledgement during G3
Twice
NSF: Once
0
transmission
DIS: Twice
7
Non-modulated carrier for V29 transmission
Yes
No
0
mode
8
EOL detect timer
25 s
13 s
0
Modem speed
V.33
V.17
V.29
V.27 ter
14400 12000 14400 12000 9600
7200
9600
7200
4800
2400
1
0
0
1
1
1
1
0
0
0
0
1
2
1
1
0
0
0
0
0
0
0
0
0
3
0
1
0
1
0
1
0
1
1
0
0
4
0
0
0
0
1
1
1
1
0
0
0
5
Sender’s information transmit
No
Yes
0
6
Reserved
0
7
Communication error treatment in RTN
No communication error
Communication error
0
sending mode (reception)
8
CNG transmission
No
Yes
0
CED tone signal interval
1000ms
750ms
500ms
75ms
1
No. 1
1
1
0
0
0
2
No. 2
1
0
1
0
0
3
MR coding
No
Yes
0
4
ECM mode
No
Yes
0
OPTION
5
ECM MMR mode
No
Yes
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
1
Signal transmission level
Binary input
0
2
No. =
16
8
4
2
1
1
3
1
2
3
4
5
0
4
0
1
0
0
0
0
5
0
6
Protocol monitor (error print)
Printed at com. error
Not printed
0
7
Protocol monitor
Yes
No
0
8
Line monitor
Yes
No
0
Digital line equalization setting (Reception)
7.2km
3.6km
1.8km
0km
1
No. 1
1
1
0
0
0
2
No. 2
1
0
1
0
1
Digital line equalization setting
7.2km
3.6km
1.8km
0km
3
(Transmission)
No. 3
1
1
0
0
0
4
No. 4
1
0
1
0
1
Digital cable equalizer setting (Reception
7.2km
0km
5
for Caller ID)
No. 5
1
0
0
6
No. 6
1
0
0
7
Error criterion
10 ~ 20 %
5 ~ 10 %
0
8
Anti junk fax check
Yes
No
1
SW
NO.
DATA
NO.
ITEM
Switch setting and function
1
0
Remarks
Initial
setting
SW
l
A1
SW
l
A2
SW
l
A3
SW
l
A5
SW
l
A4