Sharp A260 Service Manual - Page 15

Busy tone detection ON/OFF time Lower

Page 15 highlights

UX-A260U SW DATA NO. NO. ITEM 1 Reserved 2 Reserved 3 SW 4 l G2 5 6 Reserved Reserved Reserved Reserved 7 Reserved 8 Reserved 1 Reserved 2 Reserved 3 Reserved SW 4 Reserved l G3 5 Reserved 6 Reserved 7 Reserved 8 Reserved Busy tone detection ON/OFF time (Lower 1 duration) 2 Busy tone detection ON/OFF time (Upper 3 duration) SW 4 l 5 Busy tone detect continuation sound detect H1 during OGM 6 Busy tone detect continuation sound detect 7 Busy tone detect intermittent sound detect during OGM 8 Busy tone detect intermittent sound detect Busy tone detection pulse number 1 2 3 Fax switching when A.M. full SW 4 Busy tone detect continuation sound detect l frequency H2 5 Reserved 6 Reserved 7 AM OGM announce only mode 8 Busy tone continuous sound detect time ICM recording time 1 2 A.M. quiet time 1 3 SW 4 l I1 A.M. quiet time 2 5 6 7 Key input buzzer on/off switch (Two way recording mode) 8 CPC signal detection Switch setting and function 1 0 No. 1 No. 2 No. 3 No. 4 No 150ms 0 0 650ms 0 0 200ms 0 1 900ms 0 1 Yes 250ms 1 0 1500ms 1 0 No Yes No Yes No 2pulses No. 1 0 No. 2 0 Yes 320Hz - 570Hz Yes 4pulses 6pulses 0 1 1 0 No 320Hz - 460Hz Yes 5s No. 1 No. 2 No. 3 No. 4 No. 5 No. 6 On Yes 4min 0 0 2s 0 0 0s 0 0 No 10s 15s 30s 0 1 1 0 3s 4s 0 1 1 0 1s 2s 0 1 1 0 Off No 350ms 1 1 2700ms 1 1 Initial setting 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 0 0 0 0 10pulses 1 0 1 1 0 0 0 0 0 1 60s 1 0 1 0 5s 1 0 1 0 3s 1 1 1 0 0 1 Remarks OPTION OPTION OPTION OPTION 2 - 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76

UX-A260U
2 – 9
1
Reserved
0
2
Reserved
0
3
Reserved
0
4
Reserved
0
5
Reserved
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
1
Reserved
0
2
Reserved
0
3
Reserved
0
4
Reserved
0
5
Reserved
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
Busy tone detection ON/OFF time (Lower
150ms
200ms
250ms
350ms
1
duration)
No. 1
0
0
1
1
0
2
No. 2
0
1
0
1
1
Busy tone detection ON/OFF time (Upper
650ms
900ms
1500ms
2700ms
3
duration)
No. 3
0
0
1
1
0
4
No. 4
0
1
0
1
1
5
Busy tone detect continuation sound detect
No
Yes
0
during OGM
6
Busy tone detect continuation sound detect
No
Yes
0
7
Busy tone detect intermittent sound detect
No
Yes
0
during OGM
8
Busy tone detect intermittent sound detect
No
Yes
0
Busy tone detection pulse number
2pulses
4pulses
6pulses
10pulses
1
No. 1
0
0
1
1
0
2
No. 2
0
1
0
1
1
3
Fax switching when A.M. full
Yes
No
0
OPTION
4
Busy tone detect continuation sound detect
320Hz - 570Hz
320Hz - 460Hz
0
frequency
5
Reserved
0
6
Reserved
0
7
AM OGM announce only mode
Yes
No
0
OPTION
8
Busy tone continuous sound detect time
5s
10s
1
ICM recording time
4min
15s
30s
60s
OPTION
1
No. 1
0
0
1
1
0
2
No. 2
0
1
0
1
0
A.M. quiet time 1
2s
3s
4s
5s
3
No. 3
0
0
1
1
0
4
No. 4
0
1
0
1
0
A.M. quiet time 2
0s
1s
2s
3s
5
No. 5
0
0
1
1
1
6
No. 6
0
1
0
1
0
7
Key input buzzer on/off switch (Two way
On
Off
0
recording mode)
8
CPC signal detection
Yes
No
1
OPTION
SW
l
G2
SW
NO.
DATA
NO.
ITEM
Switch setting and function
1
0
Remarks
Initial
setting
SW
l
G3
SW
l
H1
SW
l
H2
SW
l
I1