Sharp CD-E500 Service Manual - Page 13

Preset frequencies for various destinations, random preset memory, Electronic volume Test Mode TEST

Page 13 highlights

3.Preset frequencies for various destinations (random preset memory) CH BAND FM 1 FM 87.5 MHz 2 FM108.0 MHz 3 FM FM 98.0 MHz 4 STEREO FM 90.0 MHz 5 FM106.0 MHz CH BAND 6 7 8 AM 9 10 AM AM 530 kHz AM1720 kHz AM 990 kHz AM 600 kHz AM1400 kHz CH 16-35 36 37 38 39 40 BAND FM MONO FM FM106.0 MHz FM 90.0 MHz FM 98.0 MHz FM108.0 MHz FM 87.5 MHz • The slant line sections of the table store no memory. 4. Electronic volume Test Mode (TEST 3) When this test mode is obtained, the following display lights for one second. CD-E500 CD-E55/E44 5. Timer test Mode (TEST 4) When this test mode is obtained, the following display lights for one second. Set the current time and timer time according to the following procedure to reproduce the timer. 1.Set the current time to 1:00, the timer to ON time 1:05, the function to CD, and volume to STEP 12, respectively. One minute is counted as one second, and the timer is reproduced. The fade-in (when playback is started) is executed at a rate of one step for 1 sec. After completion of fade-in, the fadeout is executed at a rate of one step for 1 sec (WAIT 1 sec inserted). After completion of fade-out, the power is turned off (after WAIT 1 sec), and the mode is shifted to the standby. The display during operation is the same as that of ordinary timer operation. 6. FL Test Mode (TEST 5) When the FL test mode is obtained, all the FL segments are lighted. Then pressing the "PLAY" button switches display as below. Lighting of all segments Lighting of odd segments In this mode, volume is Volume -14 dB (STEP23), FLAT AND X-BASS ON, and start-up function to CD, respectively. The button operations in the test mode are the same as those of ordinary operation except volume UP/DOWN. (1) The display is the same as that of ordinary operation except test mode setting. (2) Unlike the ordinary state, the volume is controlled with the volume UP/DOWN button in accordance with the following three steps. ∞ Volume- (STEP 0) Volume-14 dB (STEP 23) Volume-0 (STEP 30) (3) X-BASS is switched when button is pressed.. Lighting of even segments - 13 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

– 13 –
CD-E500
CD-E55/E44
3.Preset frequencies for various destinations
(random preset memory)
BAND
6
AM
530 kHz
7
AM1720 kHz
8
AM
AM
990 kHz
9
AM
600 kHz
10
AM1400 kHz
AM
CH
BAND
16-35
36
FM106.0 MHz
37
FM
90.0 MHz
38
FM
FM
98.0 MHz
39
MONO
FM108.0 MHz
40
FM
87.5 MHz
FM
CH
• The slant line sections of the table store no memory.
BAND
1
FM
87.5 MHz
2
FM108.0 MHz
3
FM
FM
98.0 MHz
4
STEREO
FM
90.0 MHz
5
FM106.0 MHz
FM
CH
4. Electronic volume Test Mode (TEST 3)
When this test mode is obtained, the following display lights
for one second.
In this mode, volume is Volume -14 dB (STEP23), FLAT
AND X-BASS ON, and start-up function to CD, respectively.
The button operations in the test mode are the same as
those of ordinary operation except volume UP/DOWN.
(1) The display is the same as that of ordinary operation
except test mode setting.
(2)
Unlike the ordinary state, the volume is controlled with
the volume UP/DOWN button in accordance with the
following three steps.
Volume-
(STEP 0) <-> Volume-14 dB (STEP 23) <-
> Volume-0 (STEP 30)
(3) X-BASS is switched when button is pressed..
5. Timer test Mode (TEST 4)
When this test mode is obtained, the following display lights
for one second.
Set the current time and timer time according to the following
procedure to reproduce the timer.
1.Set the current time to 1:00, the timer to ON time 1:05, the
function to CD, and volume to STEP 12, respectively.
One
minute is counted as one second, and the timer is reproduced.
The fade-in (when playback is started) is executed at a rate
of one step for 1 sec.
After completion of fade-in, the fade-
out is executed at a rate of one step for 1 sec (WAIT 1 sec
inserted).
After completion of fade-out, the power is turned off (after
WAIT 1 sec), and the mode is shifted to the standby.
The display during operation is the same as that of ordinary
timer operation.
6. FL Test Mode (TEST 5)
When the FL test mode is obtained, all the FL segments are
lighted. Then pressing the "PLAY" button switches display
as below.
Lighting of all segments
Lighting of odd segments
Lighting of even segments