POWER switch. - parts
![]() |
UPC - 074000347502
View all Sharp PG-D120U manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
Caution: Because some parts may not be sufficiently cooled, be sure to remove the lamp cage by the handle while taking care not to touch the metallic areas. Note: Do not allow anything to hit the UV filter (j). Installing the lamp unit 1. Hold lamp cage (h) by the handle (g) and press it in firmly while making sure that the lamp cage (h) properly connects to the connector (i). 2. Tighten screws (e), (f) and (d), then perform the above instructions in the reverse order. Resetting the lamp timer OFF ON 1. Plug in the power cord. OFF ON MN EN LAMP 0000H 2. While depressing the ADJUSTMENT , ADJUSTMENT , and ENTER buttons on the projector, turn on the MAIN POWER switch. 3. Press the POWER ON/OFF button on the projector or the power on button on the remote control to turn on the power. After the unit projector turns on, "LAMP 0000H" will be displayed to signify that the lamp timer is reset. Notes: • After replacing lamp, be sure to reset the lamp timer. If you do not, the LAMP REPLACEMENT indicator and "LAMP" display will not disappear. • Only reset the lamp timer after replacing the lamp. E-33