Sony PDW510 Operation Manual - Page 198

the event of BATTERY BEFORE END/DISC, Sets DF or NDF mode.

Page 198 highlights

Appendixes No. Page 09 TIMECODE 10 VDR MODE Item TC OUT Settings AUTO/GENE Default AUTO DF/NDF DF/NDF DF (PDW-510/530 only) EXT-LK DF/NDF INT/EXT INT (PDW-510/530 only) EXT-LK UBIT INT/EXT INT LTC UBIT FIX/TIME FIX VITC UBIT FIX/TIME FIX WATCH AUTO ADJ OFF/ON ON UBIT GROUP ID 000/101 000 VITC INS LINE 1 9 to 22 H (PDW- 16H 510P/530P) 12 to 19 H (PDW- 19H 510/530) VITC INS LINE 2 12 to 19 H (PDW- 18H 510/530) 9 to 22 H (PDW- 21H 510P/530P) REC TALLY BLINK OFF/ON ON REC START BEEP OFF/ON OFF SUB LCD MODE SEL TIMER/OFF/CONT TIMER SUB LCD TIMER 1H/3H/8H 1H REC FORMAT (PDW-530/530P only) IMX50/IMX40/ IMX30/DVCAM IMX50 Description Selects the time code signal output. AUTO: Outputs the time code generator output during recording and outputs the time code reader output during playback. GENE: Outputs the time code generator output during recording and playback. Sets DF or NDF mode. DF: Drop frame mode NDF: Non-drop frame mode Selects either internal setting or external setting for DF/NDF. INT: Internal EXT: External Sets whether the LTC UBIT setup value locks to an INT or an EXT source when the time code is locked to an external source. INT: Internal lock EXT: External lock Sets the data to be recorded in UBIT of LTC. FIX: Records the data that is set by the user. TIME: Records the present time. Sets the data to be recorded in UBIT of VITC. FIX: Records the data that is set by the user. TIME: Records the present time. Matches the time of the built-in clock with the time data of the user bits of an external time code. Turns the automatic time correction function of the built-in clock on or off. Selects the UBIT GROUP ID. Selects the line into which VITC is to be inserted. Selects the line into which VITC is to be inserted. Turns the tally illumination control on or off in the event of BATTERY BEFORE END/DISC BEFORE END. Turns on or off the alarm sound at REC START/STOP. Sets the time code (TC) display after poweroff as follows. TIMER: The TC display turns off after the elapse of the time set by the SUB LCD TIMER below. OFF: Not displayed. CONT: Displayed. Sets the duration of time after which the TC display is to be turned off after power-off, when the SUB LCD MODE SEL item, above, is set to TIMER (H: hours). Selects the type of video codec. Multiple codecs cannot be mixed on one disc. 198 Menu List

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216

Appendixes
198
Menu List
09
TIMECODE
TC OUT
AUTO/GENE
AUTO
Selects the time code signal output.
AUTO: Outputs the time code generator
output during recording and outputs the
time code reader output during playback.
GENE: Outputs the time code generator
output during recording and playback.
DF/NDF
(PDW-510/530 only)
DF/NDF
DF
Sets DF or NDF mode.
DF: Drop frame mode
NDF: Non-drop frame mode
EXT-LK DF/NDF
(PDW-510/530 only)
INT/EXT
INT
Selects either internal setting or external
setting for DF/NDF.
INT: Internal
EXT: External
EXT-LK UBIT
INT/EXT
INT
Sets whether the LTC UBIT setup value locks
to an INT or an EXT source when the time
code is locked to an external source.
INT: Internal lock
EXT: External lock
LTC UBIT
FIX/TIME
FIX
Sets the data to be recorded in UBIT of LTC.
FIX: Records the data that is set by the user.
TIME: Records the present time.
VITC UBIT
FIX/TIME
FIX
Sets the data to be recorded in UBIT of
VITC.
FIX: Records the data that is set by the user.
TIME: Records the present time.
WATCH AUTO ADJ
OFF/ON
ON
Matches the time of the built-in clock with the
time data of the user bits of an external time
code. Turns the automatic time correction
function of the built-in clock on or off.
UBIT GROUP ID
000/101
000
Selects the UBIT GROUP ID.
VITC INS LINE 1
9 to 22 H (PDW-
510P/530P)
16H
Selects the line into which VITC is to be
inserted.
12 to 19 H (PDW-
510/530)
19H
VITC INS LINE 2
12 to 19 H (PDW-
510/530)
18H
Selects the line into which VITC is to be
inserted.
9 to 22 H (PDW-
510P/530P)
21H
10
VDR MODE
REC TALLY BLINK
OFF/ON
ON
Turns the tally illumination control on or off in
the event of BATTERY BEFORE END/DISC
BEFORE END.
REC START BEEP
OFF/ON
OFF
Turns on or off the alarm sound at REC
START/STOP.
SUB LCD MODE
SEL
TIMER/OFF/CONT
TIMER
Sets the time code (TC) display after power-
off as follows.
TIMER: The TC display turns off after the
elapse of the time set by the SUB LCD
TIMER below.
OFF: Not displayed.
CONT: Displayed.
SUB LCD TIMER
1H/3H/8H
1H
Sets the duration of time after which the TC
display is to be turned off after power-off,
when the SUB LCD MODE SEL item, above,
is set to TIMER (H: hours).
REC FORMAT
(PDW-530/530P
only)
IMX50/IMX40/
IMX30/DVCAM
IMX50
Selects the type of video codec. Multiple
codecs cannot be mixed on one disc.
No.
Page
Item
Settings
Default
Description