Sony PDW510 Operation Manual - Page 201

Gl Sc 0/180 Sel, Delete Last Clip

Page 201 highlights

Appendixes No. Page Item Settings Default Description 16 GENLOCK GENLOCK OFF/ON ON Turns genlock on and off. RETURN VIDEO OFF/ON OFF Turns return video on and off. GL H PHASE (-60 to +139) 0 (PDW-510/530) Genlock H phase setting. (-59 to +142) 0 (PDW-510P/530P) GL SC PHASE (-99 to +99) 0 Genlock subcarrier phase setting GL SC 0/180 SEL 0/180 180 Genlock subcarrier phase setting 17 ND COMP ND OFFSET (PDW-530/530P ADJUST only) OFF/ON - Turns on and off the mode which sets ND (neutral density) filter color compensation values. CLEAR ND - OFFSET EXEC Clears ND filter color compensation values. 18 AUTO SHADING AUTO BLK SHADING EXEC EXEC Execute the auto black shooting function. RESET BLK SHD EXEC EXEC Clears black shooting compensation values. TEST OUT SELECT ENC/R/G/B ENC Selects the signal output to the TEST OUT connector. MASTER GAIN (TMP) -3/0/3/6/9/12/18/ 0 dB 24/30/36/42/48 dB Temporarily sets the master gain value. 19 DISC DELETE LAST CLIP EXEC EXEC Delete the last clip. DELETE ALL CLIPS EXEC EXEC Delete all clips on the disc. QUICK FORMAT EXEC EXEC Formats the disc. All the recorded data is deleted. 20 NETWORK DHCP ENABL/DSABL DSABL Selects whether to enable automatic acquisition of the IP address from a DHCP server. IP ADDRESS xxx.xxx.xxx.xxx 192.168.1 Sets the IP address. .10 SUBNET MASK xxx.xxx.xxx.xxx 255.255.2 Sets the subnet mask. 55.0 DEF. GATEWAY xxx.xxx.xxx.xxx 0.0.0.0 Sets the default gateway. LINK SPEED AUTO/10 Mbps/ 100 Mbps AUTO Sets the communications speed. DUPLEX AUTO/FULL/HALF AUTO Sets the duplex mode. 1) The setting of this item is overridden by the setting of BEFORE END 3 when TYPE DETECTION in the BATTERY 2 page is set to OTHER. 2) The setting of this item is overridden by the setting of END 3 when TYPE DETECTION in the BATTERY 2 page is set to OTHER. 3) This is supported from firmware version 1.4. 4) When TYPE DETECTION in the BATTERY 2 page is set to AUTO, any batteries other than Sony BP-series batteries and Anton Bauer intelligent battery systems are classified as "Others". 5) Flashes once per second when the battery status is "BEFORE END", and flashes 4 times per second when the battery status is "END". 6) This is supported from firmware version 1.5 Menu List 201

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216

Appendixes
201
Menu List
1) The setting of this item is overridden by the setting of BEFORE END 3
when TYPE DETECTION in the BATTERY 2 page is set to OTHER.
2) The setting of this item is overridden by the setting of END 3 when TYPE
DETECTION in the BATTERY 2 page is set to OTHER.
3) This is supported from firmware version 1.4.
4) When TYPE DETECTION in the BATTERY 2 page is set to AUTO, any
batteries other than Sony BP-series batteries and Anton Bauer intelligent
battery systems are classified as “Others”.
5) Flashes once per second when the battery status is “BEFORE END”, and
flashes 4 times per second when the battery status is “END”.
6) This is supported from firmware version 1.5
16
GENLOCK
GENLOCK
OFF/ON
ON
Turns genlock on and off.
RETURN VIDEO
OFF/ON
OFF
Turns return video on and off.
GL H PHASE
(–60 to +139)
(PDW-510/530)
0
Genlock H phase setting.
(–59 to +142)
(PDW-510P/530P)
0
GL SC PHASE
(–99 to +99)
0
Genlock subcarrier phase setting
GL SC 0/180 SEL
0/180
180
Genlock subcarrier phase setting
17
ND COMP
(PDW-530/530P
only)
ND OFFSET
ADJUST
OFF/ON
Turns on and off the mode which sets ND
(neutral density) filter color compensation
values.
CLEAR ND
OFFSET
EXEC
Clears ND filter color compensation values.
18
AUTO SHADING
AUTO BLK
SHADING
EXEC
EXEC
Execute the auto black shooting function.
RESET BLK SHD
EXEC
EXEC
Clears black shooting compensation values.
TEST OUT SELECT
ENC/R/G/B
ENC
Selects the signal output to the TEST OUT
connector.
MASTER GAIN
(TMP)
–3/0/3/6/9/12/18/
24/30/36/42/48 dB
0 dB
Temporarily sets the master gain value.
19
DISC
DELETE LAST CLIP
EXEC
EXEC
Delete the last clip.
DELETE ALL CLIPS
EXEC
EXEC
Delete all clips on the disc.
QUICK FORMAT
EXEC
EXEC
Formats the disc. All the recorded data is
deleted.
20
NETWORK
DHCP
ENABL/DSABL
DSABL
Selects whether to enable automatic
acquisition of the IP address from a DHCP
server.
IP ADDRESS
xxx.xxx.xxx.xxx
192.168.1
.10
Sets the IP address.
SUBNET MASK
xxx.xxx.xxx.xxx
255.255.2
55.0
Sets the subnet mask.
DEF. GATEWAY
xxx.xxx.xxx.xxx
0.0.0.0
Sets the default gateway.
LINK SPEED
AUTO/10 Mbps/
100 Mbps
AUTO
Sets the communications speed.
DUPLEX
AUTO/FULL/HALF
AUTO
Sets the duplex mode.
No.
Page
Item
Settings
Default
Description