Stihl FSA 90 R Instruction Manual - Page 28
Maintenance and Care
View all Stihl FSA 90 R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
English Maintenance and Care The following intervals apply to normal operating conditions only. If your daily working time is longer or operating conditions are difficult (very dusty work area, etc.), shorten the specified intervals accordingly. Move the retaining latch to ƒ and remove the battery before performing any work on the power tool. Complete unit Controls (retaining latch, trigger switch lockout, trigger switch) All accessible screws and nuts Battery Battery compartment Cutting attachment Safety labels Visual inspection (condition) Clean Replace any damaged parts Check operation Clean Retighten Visual inspection Clean Check operation (eject battery) Visual inspection Replace Check tightness Replace X X X X X X X X X X before starting work after finishing work or daily weekly monthly every 12 months if problem if damaged as required X X X X X X X 26 FSA 90 R