Sub-Zero BI-36S Built-In Installation Guide - Page 13
Site Preparation, Plumbing Requirements
View all Sub-Zero BI-36S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
Site Preparation 13 subzero.com/specs Plumbing Requirements All built-in models with an automatic ice maker feature a water filtration system that supplies filtered water to the ice maker and water dispenser (dispenser models). The water supply line should be located within the shaded area shown in the illustrations. The water supply line should be connected to the house supply with an easily accessible shut-off valve between the supply and the unit. Do not use self-piercing valves. A saddle valve kit is available through your authorized Sub-Zero dealer. The water line must not interfere with installation of the anti-tip brackets. A reverse osmosis system can be used provided there is constant water pressure of 20 psi (1.4 bar) to 120 psi (8.3 bar) supplied to the unit at all times. In this application, the water filtration system must be bypassed. Refer to water filter bypass mode on page 21. A copper line is not recommended for this application. IMPORTANT NOTE: All installations must meet local plumbing code requirements. 18" (457) FLOOR 6" (152) 3" (76) FRONT VIEW 1/2" BACK WALL (13) 18" (457) 6" (152) TOP VIEW Location of water supply- rear. Location of water supply- bottom. Plumbing Requirements Water Supply Line 1/4" OD copper, braided stainless steel or PEX tubing Water Pressure 35-120 psi (2.8-8.2 bar) Excess Water Line for Connection 36" (914)