New functions in firmware version 1.30

Page 29 highlights

DA-6400/DA-6400dp New functions in firmware version 1.30 The following new functions have been added in firmware version 1.30. 00DA-6400 Control iPad remote control app support added 00TASCAM IF-AE16 AES/EBU interface card support added 00Function added to synchronize with SMPTE timecode and play the current take 00VAMPING mode added to repeat playback function modes 00Function added to set the input and output signal routing for each individual channel 00On/off setting added for NO SIGNAL error checking function 00Function added that requires pressing and holding the button to stop recording TASCAM DA-6400 Control iPad remote control app support added The TASCAM DA-6400 Control iPad remote control app is now supported. TASCAM IF-AE16 AES/EBU interface card support added The TASCAM IF-AE16 AES/EBU interface card is now supported. If installed in SLOT 1 or SLOT 2 of this unit, the following appears on the SLOT1 or SLOT2 menu page. CLOCK LINE If the slot with the IF-AE16 card installed is selected to be the clock master for the unit, this selects the signal line to use as the clock master. Options: A ES 1-2 (default), AES 3-4, AES 5-6, AES 7-8, AES 9-10, AES 11-12, AES 13-14, AES 15-16 NOTE ii When the slot with the IF-AE16 card installed is selected to be the clock master, you can also set the CLOCK LINE item on the CLOCK screen that opens from the GENERAL page CLOCK MASTER item. Moreover, if the slot with the IF-AE16 installed is selected to be the clock master, you can also change the setting by moving the cursor to APPLY and pressing the MULTI JOG dial. ii If the SRC item is set to ON for a signal line, it cannot be selected as the master clock In this case, the following pop-up window appears. A confirmation pop-up message appears.A confirmation pop-up message appears. SRC This turns the sample rate converter on/off for each signal line Options: OFF (default value), ON NOTE ii SRC cannot be set to ON for the signal line selected as the master clock. In this case, the following pop-up window appears.A confirmation pop-up message appears. ii If an IF-AE16 is installed, depending on the main unit SRC item setting and clock master setting, an error described as "SRC for the IF-AE16 signal line selected as the CLOCK MASTER is ON" could occur. In this case, the SRC item for that signal line will be turned off automatically and the INFO indicator will light red. In this situation, press the INFO button to open the following alert message. Once this has been confirmed, it will disappear. TASCAM DA-6400/DA-6400dp 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

TASCAM
DA-6400/DA-6400dp
29
DA-6400/DA-6400dp
New functions in firmware version 1.30
The following new functions have been added in firmware version 1.30.
0
DA-6400 Control iPad remote control app support added
0
TASCAM IF-AE16 AES/EBU interface card support added
0
Function added to synchronize with SMPTE timecode and play the current take
0
VAMPING mode added to repeat playback function modes
0
Function added to set the input and output signal routing for each individual channel
0
On/off setting added for NO SIGNAL error checking function
0
Function added that requires pressing and holding the button to stop recording
TASCAM DA-6400 Control iPad remote control app support added
The TASCAM DA-6400 Control iPad remote control app is now supported.
TASCAM IF-AE16 AES/EBU interface card support added
The TASCAM IF-AE16 AES/EBU interface card is now supported.
If installed in
SLOT 1
or
SLOT 2
of this unit, the following ap-
pears on the
SLOT1
or
SLOT2
menu page.
CLOCK LINE
If the slot with the IF-AE16 card installed is selected to be the
clock master for the unit, this selects the signal line to use as
the clock master.
Options:
AES 1-2
(default),
AES 3-4
,
AES 5-6
,
AES 7-8
,
AES 9-10
,
AES 11-12
,
AES 13-14
,
AES 15-16
NOTE
i
When the slot with the IF-AE16 card installed is selected
to be the clock master, you can also set the
CLOCK LINE
item on the
CLOCK
screen that opens from the
GENERAL
page
CLOCK MASTER
item. Moreover, if the slot with the
IF-AE16 installed is selected to be the clock master, you can
also change the setting by moving the cursor to
APPLY
and
pressing the
MULTI JOG
dial.
i
If the
SRC
item is set to
ON
for a signal line, it cannot be se-
lected as the master clock In this case, the following pop-up
window appears. A confirmation pop-up message appears.A
confirmation pop-up message appears.
SRC
This turns the sample rate converter on/off for each signal
line
Options:
OFF
(default value),
ON
NOTE
i
SRC
cannot be set to
ON
for the signal line selected as the
master clock. In this case, the following pop-up window
appears.A confirmation pop-up message appears.
i
If an IF-AE16 is installed, depending on the main unit
SRC
item setting and clock master setting, an error described as
“SRC for the IF-AE16 signal line selected as the CLOCK MAS-
TER is ON” could occur.
In this case, the
SRC
item for that signal line will be turned
off automatically and the
INFO
indicator will light red. In this
situation, press the
INFO
button to open the following alert
message. Once this has been confirmed, it will disappear.