Thermador HMIB42WS Installation instructions - Page 12

Venting Methods, For Non-Vented recirculating Installations

Page 12 highlights

Common Ducting Conigurations RECIRCULATING MODE VENTING THROUGH THE CEILING C B B A A A. 8" round transition B. 8" round duct system C. Recirculating kit NOTE: The igure does not represent all conigurations or installation methods. The image is to be used as a guide ONLY. Venting Methods This hood is factory set for venting through the roof (vertical discharge). A 8" (203 mm) round duct system is needed for installation (not included). NOTE: Flexible duct is not recommended. Flexible ductwork creates back pressure and air turbulence that greatly reduce performance. Vent system can terminate either through the roof. Always install a metal vent cover where the ductwork exits the house. For Non-Vented (recirculating) Installations If it is not possible to vent cooking fumes and vapors to the outside, the hood can be used in the non-vented (recirculating) version, using the recirculating kit . Fumes and vapors are recycled through the round grid. See optional accessories section. English | 12 | Installation Instructions

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

Installation Instructions
English | 12 |
Common Ducting ConIgurations
RECIRCULATING MODE
VENTING THROUGH THE CEILING
A. 8” round transition
B. 8” round duct system
C. Recirculating kit
A
B
C
A
B
NOTE:
The Igure does not represent all conIgurations or installation methods. The image is to be used as a guide ON²Y.
Venting Methods
This hood is factory set for venting through the roof (vertical
discharge). A 8” (203 mm) round duct system is needed for
installation (not included).
NOTE:
Flexible duct is not recommended. Flexible
ductwork creates back pressure and air turbulence that
greatly reduce performance.
Vent system can terminate either through the roof.
Always install a metal vent cover where the ductwork exits
the house.
For Non-Vented (recirculating) Installations
If it is not possible to vent cooking fumes and vapors to
the outside, the hood can be used in the non-vented
(recirculating) version, using the recirculating kit . Fumes
and vapors are recycled through the round grid.
See optional accessories section.