7. Install the structure to the horizontal support (previously attached to the ceiling) with 16 - 4.2 x 8 mm screws. A 2. Attach the blower housing to the lower vertical supports with 2 leveling screws. 3. Secure it with 16 installation screws. See the image below. B B. A. Upper horizontal support B. 16 - 4.2x8 mm screws Mounting the blower housing on the structure 1. Slide the blower housing under the structure. Mounting the upper duct covers 1. Get together the upper duct covers and assembly them. • Slide the edge of the duct cover under the clip located in the opposite duct cover. • Push them until you hear a click. The bulges on the edge of the duct covers has to enter in the clip slots. Installation Instructions English | 15 |
Installation Instructions
English | 15 |
7. Install the structure to the horizontal support (previously
attached to the ceiling) with 16 - 4.2 x 8 mm screws.
A
B
B.
A. Upper horizontal support
B. 16 - 4.2x8 mm screws
Mounting the blower housing on the
structure
1. Slide the blower housing under the structure.
2. Attach the blower housing to the lower vertical supports
with 2 leveling screws.
3. Secure it with 16 installation screws. See the image
below.
Mounting the upper duct covers
1. Get together the upper duct covers and assembly them.
•
Slide the edge of the duct cover under the clip
located in the opposite duct cover.
•
Push them until you hear a click. The bulges on the
edge of the duct covers has to enter in the clip
slots.