Thermador PRG304GH Installation Instructions - Page 5
Important, NOTICE - ratings
View all Thermador PRG304GH manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
• For island installations, the hood width should, at a minimum, overhang the range by 3" on each side. Important: Ventilation hoods and blowers are designed for use with single wall ducting. However, some local building codes or inspectors may require double wall ducting. Consult local building codes and/or local agencies, before starting, to assure that hood and duct installation will meet local requirements. Do not install a microwave oven/ventilator combination above the range, as these type of units do not provide the proper ventilation and are not suitable for use with the range. 2. Hood Placement: • For best smoke elimination, the lower edge of the hood should be installed 30" above the range cooking surface. (See Figure 1). NOTICE: Most range hoods contain combustible components which must be considered when planning the installation. • If the hood contains any combustible materials (i.e. a wood covering), it must be installed a minimum of 40" above the cooking surface. 3. Consider Make-Up Air: • Due to the high volume of ventilation air, a source of outside replacement air is recommended. This is particularly important for tightly sealed and insulated homes. • A qualified heating and ventilating contractor should be consulted. Range Width Range Top Configuration Ventilation Options 30" 4 burners 30" or 36" Pro Wall Hood 30" or 36" Custom Insert w/ optional blower 42" Island Hood w/ optional blower 4 burners with griddle 36" 6 burners 36" or 42" Pro Wall Hood 36" Custom Insert w/ optional blower 42" or 48" Island Hood w/ optional blower 48" 6 burners with griddle 48" or 54" Pro Wall Hood ** 48" Custom Insert w/ optional blower Important Notes: • It is recommended that a Thermador Professional wall or island hood or custom insert is used with Thermador Professional Ranges. • The HPWB or PH Professional Series Wall Hoods or the Professional Series Custom Inserts are recommended ventilation solutions for these ranges. • Refer to www.Thermador.com for a complete selection of Professional Ventilation options, Blowers, and Accessories. • For high output gas ranges (60,000 BTU or greater), the minimum of one (1) CFM of ventilation per 100 BTU is recommended. If the range has a griddle, add 200 CFM to the estimated blower capacity. Additional blower capacity may be required for longer duct runs. • For island applications, it is recommended to use a hood width that exceeds the width of the range by 6" (overlapping the range by a minimum of 3" on each end). • ** Not all 48" Pro Wall Hood models can accommodate a 1,300 CFM blower option. • CFM = "cubic feet per minute" (standard blower capacity rating). English 3