URC DMS-AV Owners Manual - Page 24
Configuration and Control - Hardware, Connections
![]() |
View all URC DMS-AV manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
DMS-AV HOME THEATER AMPLIFIER Configuration and Control - Hardware Connections Ethernet Communication - Connection Instructions 1. Make sure that all devices are powered Off, including the DMS-AV, PCs, routers, switches, etc. 2. Connect one end of an Ethernet network cable to one of the numbered ports on the back of the router. Connect the other end to the Ethernet port in the rear of the DMS-AV. Repeat this step to connect more PCs or other network devices that require a wired connection to the router. Power the router as needed. 3. Connect your cable or DSL modem's Ethernet cable to the router's Internet port. Power On the cable or DSL modem, DMS-AV, router, etc. 4. Power On your PC(s). Infrared Input The DMS-AV allows for basic infrared control via the IR Input port. Connect an Infrared receiver, such as a URC MRF-350 IR/RF Base Station to the infrared input port on the back of the DMS-AV. The DMS-AV does not support a built-in front panel infrared receiver. All connections are 3.5mm (mono mini) jack, with the tip positive(+), and the sleeve being ground. MRF-350 RF Base Station to DMS-AV IR Input Page 25