Uniden BC246T English Owners Manual - Page 50

Cloning the Scanner

Page 50 highlights

• 19200 bps The baud rate is set to 19,200 bps. • 38400 bps The baud rate is set to 38,400 bps. • 57600 bps The baud rate is set to 57,600 bps. Cloning the Scanner To clone (copy) data from one BC246T scanner to another BC246T scanner, you must first connect the scanners to each other using the included connection cables and a DB9 null modem adapter and DB9 gender changer (neither included), available at most computer stores. Then you must set one scanner as the master (source) and the other as the slave (destination). Plug the smaller end of each of the included connection cables into Remote on the right side of each scanner. Then connect the other end of the cables together using the null modem connector and gender changer. Then set up both scanners. Menu Xfer Information E Clone E • Master This will be the master (source) scanner. • Slave This will be the slave (destination) scanner. (Master scanner) Clone Master Press SCAN Key E (Slave scanner) Clone Slave Press SCAN Key E When you are ready to clone the scanner, press Scan on the slave scanner first, then on the master scanner. The master scanner checks the connection between the two scanners, then transfers its data to the slave scanner. When the transfer is complete, Complete appears on both scanners. If the transfer did not work, Error appears on the master scanner. Other Settings 50

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

50
Other Settings
19200 bps
The
baud rate is set to 19,200 bps.
38400 bps
The baud rate is set to 38,400 bps.
57600 bps
The baud rate is set to 57,600 bps.
Cloning the Scanner
To clone (copy) data from one BC246T scanner to another
BC246T scanner, you must first connect the scanners to
each other using the included connection cables and a
DB9 null modem adapter and DB9 gender changer
(neither included), available at most computer stores.
Then you must set one scanner as the master (source)
and the other as the slave (destination).
Plug the smaller end of each of the included connection
cables into
Remote
on the right side of each scanner.
Then connect the other end of the cables together using
the null modem connector and gender changer.
Then set up both scanners.
J
4
Xfer Information
J
E
J
Clone
J
E
J 4
Master
This will be the master (source) scanner.
Slave
This will be the slave (destination) scanner.
(Master scanner)
Clone Master Press SCAN Key
J
E
(Slave scanner)
Clone Slave Press SCAN Key
J
E
J
When you are ready to clone the scanner, press
Scan
on
the slave scanner first, then on the master scanner.
The master scanner checks the connection between the
two scanners, then transfers its data to the slave scanner.
When the transfer is complete,
Complete
appears on both
scanners. If the transfer did not work,
Error
appears on
the master scanner.
Menu