Uniden BC246T English Owners Manual - Page 91
Finding Repeater Output Frequencies, Setting the Maximum Auto Store Value, Setting the Modulation
View all Uniden BC246T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 91 highlights
Finding Repeater Output Frequencies Menu Srch/CloCall Opt E Repeater Find E This feature sets whether the scanner tries to tune to a repeater output frequency during Close Call operation when it detects a transmission on a repeater input frequency. Since you can normally only hear one side of a conversation when you listen to an input frequency transmission, turning this feature on can let you hear both sides of the conversation. On The scanner automatically applies repeater reverse to detected transmissions. If the scanner detects the transmission on the output frequency, it beeps, REPEATER FIND appears, and it remains on the output frequency until transmissions end. If it does not detect a transmission on the output frequency, it remains on the original frequency. Off The scanner does not try to find the output frequency. Setting the Maximum Auto Store Value Menu Srch/CloCall Opt E Max Auto Store E This value sets how many hits the scanner will automatically store when it is in either Search and Store or Close Call Auto Store mode. Use the number keys to enter a value from 1 - 256, then press E. When the scanner reaches the maximum number of hits you set, it stops the auto-store operation. Setting the Modulation Type Menu Srch/CloCall Opt E Set Modulation E Search and Close Call Options 91