Uniden BCD160DN English Owners Manual - Page 50

HOLD Mode HOLD

Page 50 highlights

MAX Mode "Max" shows in the display and will freeze the signal strength bars at their strongest signals. To toggle between Search mode and Max Hold Search mode, press FUNC + SCAN/ srch. HOLD Mode (HOLD) HOLD Mode "HOLD" displays and allows you hold the sweep then scroll to and listen to that frequency. You can use the scroll control knob to move the frequency marker to other locations, including the center frequency, and listen to that frequency. To toggle between Hold mode and Search/Max Hold Search mode, press HOLD. Center frequency marker stops flashing in Hold mode. NOTE: If the sweep range is set wide, a single signal bar will contain multiple frequency ranges. This is why the marker moves slowly even when you turn the scroll control knob. If you want to pinpoint the frequency, set the span range narrower. (See page 51.) NOTE: With MAX hold, the signal bar remains visible even with short duration signals. Therefore, even if you move the marker to that frequency, you may not be able to receive the signal because this is past information. To return the marker to the center frequency position while in HOLD mode, press FUNC then L/O. Press HOLD to return to Search mode. 50

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

50
MAX Mode
“Max” shows in the display and will freeze the signal strength bars at their strongest
signals.
To toggle between Search mode and Max Hold Search mode, press
FUNC
+
SCAN/
srch
.
HOLD Mode (HOLD)
HOLD
Mode
“HOLD” displays and allows you hold the sweep then scroll to and listen to that
frequency. You can use the scroll control knob to move the frequency marker to other
locations, including the center frequency, and listen to that frequency.
To toggle between Hold mode and Search/Max Hold Search mode, press
HOLD
.
Center frequency marker stops
ashing in Hold mode.
NOTE: If the sweep range is set wide, a single signal bar will contain multiple
frequency ranges. This is why the marker moves slowly even when you turn the
scroll control knob.
If you want to pinpoint the frequency, set the span range narrower. (See page 51.)
NOTE: With MAX hold, the signal bar remains visible even with short duration
signals. Therefore, even if you move the marker to that frequency, you may not be
able to receive the signal because this is past information.
To return the marker to the center frequency position while in HOLD mode, press
FUNC
then
L/O
. Press
HOLD
to return to Search mode.