Viking RDSCE2305BSS Installation Instructions - Page 10

Leveling/Adjustments/Alignment, cont.

Page 10 highlights

Electrical Connection (4-wire) (cont.) Bare Wire Connection Eyelet Connection 4 1 1 To make a bare wire connection, use holes on the left side of the terminal block. To connect eyelet style wires, use holes on right side of terminal. 5 Feed supply cord up through hole in bottom of range back. 6 1 2 Attach ground wire (green) with ground screw that was removed. 7 1 1 2 Attach line #1 (black) and line #2 (red) leads to outside terminal. Attach neutral wire (white) to center terminal on terminal block. 8 1 3 Push supply cord toward terminal block to relieve strain, reattach supply cord strain relief bracket over supply cord. 18 2 Reattach access door. Leveling/Adjustments/Alignment 1 2 Measure the four corners in cutout area to verify if flooring is level. 3 For uneven or sloped floors, level unit with metal shims only, as the adjustment required may exceed the thread available in the leg. 4 Move unit into opening. 5 (03.9/58"cm) Check that unit is level side to side and front to back. Side trim of the high corner must be 3/8" (0.95 cm) above countertop. 6 If leveling is required, move unit out of opening. 19 1 1 2 Lift unit and prop on wood blocks.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

19
18
4
Feed supply cord up through hole in bottom
of range back.
1
2
5
1
2
6
Attach ground wire (green)
with ground screw that was removed.
Attach line #1 (black) and line #2 (red)
leads to outside terminal. Attach neutral wire (white)
to center terminal on terminal block.
1
3
7
1
2
8
Push supply cord toward terminal
block to relieve strain, reattach supply cord strain
relief bracket over supply cord.
Reattach access door.
1
2
Measure the four corners in cutout area to
verify if flooring is level.
For uneven or sloped floors, level unit with
metal shims only, as the adjustment required may
exceed the thread available in the leg.
3
3/8”
3/8”
(0.95 cm)
(0.95 cm)
3/8”
(0.95 cm)
4
Move unit into opening.
Leveling/Adjustments/Alignment
5
Check that unit is level side to
side and front to back. Side trim of the high corner
must be 3/8” (0.95 cm) above countertop.
If leveling is required, move unit out of opening.
6
1
2
1
Lift unit and prop on wood blocks.
1
1
Eyelet Connection
Bare Wire Connection
To make a bare wire connection, use holes on the left
side of the terminal block. To connect eyelet style
wires, use holes on right side of terminal.
Electrical Connection (4-wire)
(cont.)