Yamaha CP300 Owner's Manual - Page 115

Effect Parameter List

Page 115 highlights

Effect Parameter List Items with a dot indicator (●) in the Control column are parameters that can be controlled via assignable controllers. Note that this is applicable to the Variation effects (while Insertion is selected) and to the Insertion effects. HALL 1, HALL 2, HALL M, HALL L ROOM 1, ROOM 2, ROOM 3, ROOM S, ROOM M, ROOM L STAGE 1, STAGE 2 PLATE (Reverb, Variation, Insertion block) No. Parameter 1 Reverb Time 2 Diffusion 3 Initial Delay 4 HPF Cutoff 5 LPF Cutoff 6 7 8 9 10 Dry/Wet Display 0.3 - 30.0s 0 - 10 0.1mS - 200.0mS (Rev) 0.1mS - 99.3mS (Var/Ins) Thru - 8.0kHz 1.0k - Thru Value 0 - 69 0 - 10 0 - 127 0 - 63 0 - 52 34 - 60 D63>W - D=W - DR - E=R - EW - D=W - DW - D=W - DW - D=W - DW - D=W - DR Delay 2 R ->L Delay 3 Feedback Level 4 Input Select 5 High Damp 6 7 8 9 10 Dry/Wet Display 0.1 - 1486.0ms 0.1 - 1486.0ms -63 - +63 L, R, L&R 0.1 - 1.0 D63>W - D=W - DW - D=W - D

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144

CP300 Owner’s Manual
115
Appendix
Effect Parameter List
Items with a dot indicator (
) in the Control column are parameters that can be controlled via assignable controllers.
Note that this is applicable to the Variation effects (while Insertion is selected) and to the Insertion effects.
HALL 1, HALL 2, HALL M, HALL L
ROOM 1, ROOM 2, ROOM 3, ROOM S, ROOM M, ROOM L
STAGE 1, STAGE 2
PLATE (Reverb, Variation, Insertion block)
HALL 3
HALL 4
ROOM 4
STAGE 3
PLATE 2 (Reverb)
DELAY L, C, R 1
DELAY L, C, R 2 (Variation, Insertion block)
DELAY L, R (Variation, Insertion block)
ECHO (Variation, Insertion block)
CROSS DELAY (Variation, Insertion block)
EARLY REF 1, EARLY REF 2 (Variation, Insertion block)
No.
Parameter
Display
Value
See Table
Control
1
Reverb Time
0.3 – 30.0s
0 – 69
table #4
2
Diffusion
0 – 10
0 – 10
3
Initial Delay
0.1mS – 200.0mS (Rev)
0.1mS – 99.3mS (Var/Ins)
0 – 127
0 – 63
table #5
4
HPF Cutoff
Thru – 8.0kHz
0 – 52
table #3
5
LPF Cutoff
1.0k – Thru
34 – 60
table #3
6
7
8
9
10
Dry/Wet
D63>W – D=W – D<W63
1 – 127
(table #15)
11
Rev Delay
0.1mS – 200.0mS (Rev)
0.1mS – 99.3mS (Var/Ins)
0 – 127
0 – 63
table #5
12
Density
0 – 4
0 – 4
13
Er/Rev Balance
E63>R – E=R – E<R63
1 – 127
14
High Damp
0.1 – 1.0
1 – 10
15
Feedback Level
-63 – +63
1 – 127
(table #16)
16
No.
Parameter
Display
Value
See Table
Control
1
Reverb Time
0.3 – 30.0s
0 – 69
table #4
2
Diffusion
0 – 10
0 – 10
3
Initial Delay
0.1mS – 99.3mS
0 – 63
table #5
4
HPF Cutoff
Thru – 8.0kHz
0 – 52
table #3
5
LPF Cutoff
1.0k – Thru
34 – 60
table #3
6
7
8
9
10
Dry/Wet
D63>W – D=W – D<W63
1 – 127
(table #15)
11
12
13
14
High Damp
0.1 – 1.0
1 – 10
15
16
No.
Parameter
Display
Value
See Table
Control
1
Lch Delay
0.1 – 1638.3ms
1 – 16383
2
Rch Delay
0.1 – 1638.3ms
1 – 16383
3
Cch Delay
0.1 – 1638.3ms
1 – 16383
4
Feedback Delay
0.1 – 1638.3ms
1 – 16383
5
Feedback Level
-63 – +63
1 – 127
6
Cch Level
0 – 127
0 – 127
7
High Damp
0.1 – 1.0
1 – 10
8
9
10
Dry/Wet
D63>W – D=W – D<W63
1 – 127
11
12
13
EQ Low Frequency
32Hz – 2.0kHz
4 – 40
table #3
14
EQ Low Gain
-12 – +12dB
52 – 76
15
EQ High Frequency
500Hz – 16.0kHz
28 – 58
table #3
16
EQ High Gain
-12 – +12dB
52 – 76
No.
Parameter
Display
Value
See Table
Control
1
Lch Delay
0.1 – 1638.3ms
1 – 16383
2
Rch Delay
0.1 – 1638.3ms
1 – 16383
3
Feedback Delay 1
0.1 – 1638.3ms
1 – 16383
4
Feedback Delay 2
0.1 – 1638.3ms
1 – 16383
5
Feedback Level
-63 – +63
1 – 127
6
High Damp
0.1 – 1.0
1 – 10
7
8
9
10
Dry/Wet
D63>W – D=W – D<W63
1 – 127
11
12
13
EQ Low Frequency
32Hz – 2.0kHz
4 – 40
table #3
14
EQ Low Gain
-12 – +12dB
52 – 76
15
EQ High Frequency
500Hz – 16.0kHz
28 – 58
table #3
16
EQ High Gain
-12 – +12dB
52 – 76
No.
Parameter
Display
Value
See Table
Control
1
Lch Delay1
0.1 – 1486.0ms
1 – 14860
2
Lch Feedback Level
-63 – +63
1 – 127
3
Rch Delay1
0.1 – 1486.0ms
1 – 14860
4
Rch Feedback Level
-63 – +63
1 – 127
5
High Damp
0.1 – 1.0
1 – 10
6
Lch Delay2
0.1 – 1486.0ms
1 – 14860
7
Rch Delay2
0.1 – 1486.0ms
1 – 14860
8
Delay2 Level
0 – 127
0 – 127
9
10
Dry/Wet
D63>W – D=W – D<W63
1 – 127
11
12
13
EQ Low Frequency
32Hz – 2.0kHz
4 – 40
table #3
14
EQ Low Gain
-12 – +12dB
52 – 76
15
EQ High Frequency
500Hz – 16.0kHz
28 – 58
table #3
16
EQ High Gain
-12 – +12dB
52 – 76
No.
Parameter
Display
Value
See Table
Control
1
L –>R Delay
0.1 – 1486.0ms
1 – 14860
2
R –>L Delay
0.1 – 1486.0ms
1 – 14860
3
Feedback Level
-63 – +63
1 – 127
4
Input Select
L, R, L&R
0 – 2
5
High Damp
0.1 – 1.0
1 – 10
6
7
8
9
10
Dry/Wet
D63>W – D=W – D<W63
1 – 127
11
12
13
EQ Low Frequency
32Hz – 2.0kHz
4 – 40
table #3
14
EQ Low Gain
-12 – +12dB
52 – 76
15
EQ High Frequency
500Hz – 16.0kHz
28 – 58
table #3
16
EQ High Gain
-12 – +12dB
52 – 76
No.
Parameter
Display
Value
See Table
Control
1
Type
S-H, L-H, Rdm, Rvs, Plt, Spr
0 – 5
2
Room Size
0.1 – 7.0
0 – 44
table #6
3
Diffusion
0 – 10
0 – 10
4
Initial Delay
0.1ms – 200.0ms
0 – 127
table #5
5
Feedback Level
-63 – +63
1 – 127
6
HPF Cutoff
Thru – 8.0kHz
0 – 52
table #3
7
LPF Cutoff
1.0k – Thru
34 – 60
table #3
8
9
10
Dry/Wet
D63>W – D=W – D<W63
1 – 127
11
Liveness
0 – 10
0 – 10
12
Density
0 – 3
0 – 3
13
High Damp
0.1 – 1.0
1 – 10
14
15