Yamaha Dante-MY16-AUD Dante-MY16-AUD and R Series HA Remote Control Guide - Page 14

HA control signals., the Dante-MY16-AUD in SLOT1? Those other than SLOT1 cannot transmit - firmware update

Page 14 highlights

Yamaha Commercial Audio Dante-MY16-AUD HA Remote Control Guide Note: If the mixer cannot recognize HA equipment and the HA equipment does not appear on the screen of the mixer, please check the following. ・ Are the Dante-MY16-AUD firmware and Dante Controller updated to a version that supports the HA remote function? Firmware V3.3.9 or later and Dante Controller V3.2.9 or later are required. ・ (In the case where a serial cable is used) Are you using a straight cable? ・ (In the case where control is done via the Mini-YGDAI slot) Have you inserted the Dante-MY16-AUD in SLOT1? Those other than SLOT1 cannot transmit HA control signals. ・ Is the HA Remote bridge mode of Dante-MY16-AUD set properly? ・ Is AD8HR mode set on the front panel of the R series? Are all the virtual unit IDs unique to each other? ・ Ensure that a port other than REMOTE and SLOT1 is selected as a MIDI port on the MIDI SETUP screen of the digital mixer. 14 www.yamahaproaudio.com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

Yamaha Commercial Audio
Dante-MY16-AUD
HA Remote Control Guide
14
www.yamahaproaudio.com
Note:
If the mixer cannot recognize HA equipment and the HA equipment does not
appear on the screen of the mixer, please check the following.
Are the Dante-MY16-AUD firmware and Dante Controller updated to a version
that supports the HA remote function? Firmware V3.3.9 or later and Dante
Controller V3.2.9 or later are required.
(In the case where a serial cable is used) Are you using a straight cable?
(In the case where control is done via the Mini-YGDAI slot) Have you inserted
the Dante-MY16-AUD in SLOT1? Those other than SLOT1 cannot transmit
HA control signals.
Is the HA Remote bridge mode of Dante-MY16-AUD set properly?
Is AD8HR mode set on the front panel of the R series? Are all the virtual unit
IDs unique to each other?
Ensure that a port other than REMOTE and SLOT1 is selected as a MIDI port
on the MIDI SETUP screen of the digital mixer.