Chapter 37 Access Control Table 158 SNMP Interface Traps (continued) OPTION OBJECT LABEL OBJECT ID DdmiRxPowerAlarmEventOn 1.3.6.1.4.1.890.1.5.12.46.45.2 7.2.1 DdmiVoltageAlarmEventOn 1.3.6.1.4.1.890.1.5.12.46.45.2 7.2.1 DdmiTxBiasAlarmEventOn 1.3.6.1.4.1.890.1.5.12.46.45.2 7.2.1 DdmiTemperatureWarnEven 1.3.6.1.4.1.890.1.5.12.46.45.2 tOn 7.2.1 DdmiTxPowerWarnEventOn 1.3.6.1.4.1.890.1.5.12.46.45.2 7.2.1 DdmiRxPowerWarnEventOn 1.3.6.1.4.1.890.1.5.12.46.45.2 7.2.1 DdmiVoltageWarnEventOn 1.3.6.1.4.1.890.1.5.12.46.45.2 7.2.1 DdmiTxBiasWarnEventOn 1.3.6.1.4.1.890.1.5.12.46.45.2 7.2.1 DdmiTemperatureAlarmEve 1.3.6.1.4.1.890.1.5.12.46.45.2 ntCleared 7.2.2 DdmiTxPowerAlarmEventCle 1.3.6.1.4.1.890.1.5.12.46.45.2 ared 7.2.2 DdmiRxPowerAlarmEventCl 1.3.6.1.4.1.890.1.5.12.46.45.2 eared 7.2.2 DdmiVoltageAlarmEventCle 1.3.6.1.4.1.890.1.5.12.46.45.2 ared 7.2.2 DdmiTxBiasAlarmEventClea 1.3.6.1.4.1.890.1.5.12.46.45.2 red 7.2.2 DdmiTemperatureWarnEven 1.3.6.1.4.1.890.1.5.12.46.45.2 tCleared 7.2.2 DdmiTxPowerWarnEventCle 1.3.6.1.4.1.890.1.5.12.46.45.2 ared 7.2.2 DESCRIPTION This trap is sent when a transceiver's received optical power goes over the "high alarm" threshold. This trap is sent when a transceiver's voltage goes over the "high alarm" threshold. This trap is sent when a transceiver's laser bias current goes over the "high alarm" threshold. This trap is sent when a transceiver's temperature goes over the "high warning" threshold. This trap is sent when a transceiver's transmitted optical power goes over the "high warning" threshold. This trap is sent when a transceiver's received optical power goes over the "high warning" threshold. This trap is sent when a transceiver's voltage goes over the "high warning" threshold. This trap is sent when a transceiver's laser bias current goes over the "high warning" threshold. This trap is sent when a transceiver's temperature falls down below the high alarm threshold and is back to the normal range. This trap is sent when a transceiver's transmitted optical power falls down below the high alarm threshold and is back to the normal range. This trap is sent when a transceiver's received optical power falls down below the high alarm threshold and is back to the normal range. This trap is sent when a transceiver's voltage falls down below the high alarm threshold and is back to the normal range. This trap is sent when a transceiver's laser bias current falls down below the high alarm threshold and is back to the normal range. This trap is sent when a transceiver's temperature falls down below the high warning threshold and is back to the normal range. This trap is sent when a transceiver's transmitted optical power falls down below the high warning threshold and is back to the normal range. VES1724-56 User's Guide 339