3Ware 9650SE-2LPB-10 CLI Guide - Page 31

show, includes support for an EPCT Enclosure Port Configuration Table

Page 31 highlights

show Shell Object Commands Example: //localhost> focus /c0/u0 //localhost/c0/u0> //localhost/c0/u0> focus.. //localhost/c0> //localhost> focus u0 //localhost/c0/u0> //localhost/c0> focus / //localhost> The focus command is available by default. You can disable focus by setting TW_CLI_INPUT_STYLE to old. (See "Return Code" on page 96.) (This does not apply to Mac OS X.) This command shows a general summary of all detected controllers. Note that the device drivers for the appropriate operating system should be loaded for the list to show all controllers. The intention is to provide a global view of the environment. Example: Typical output of the Show command looks like the following: //localhost> show Ctl Model Ports Drives Units NotOpt RRate VRate BBU c0 9590SE-4ME 4 4 1 0 2 5 - The output above indicates that Controller 0 is a 9590SE model with 4 Ports, with 4 Drives detected (attached), total of 1 Unit, with no units in a NotOpt (Not Optimal) state, RRate (Rebuild Rate) of 2, VRate (Verify Rate) of 5, BBU of '-' (Not Applicable). Not Optimal refers to any state except OK and VERIFYING. Other states include VERIFY-PAUSED, INITIALIZING, INITPAUSED, REBUILDING, REBUILD-PAUSED, DEGRADED, MIGRATING, MIGRATE-PAUSED, RECOVERY, INOPERABLE, and UNKNOWN. RRate also applies to initializing, migrating, and recovery background tasks. (Definitions of the unit statuses are available in the 3ware Serial ATA RAID Controller User Guide.) If you have a system with an enclosure unit, such as the 3ware Sidecar, that includes support for an EPCT (Enclosure Port Configuration Table), applicable firmware and software, and an appropriate controller (9550SX, 9590SE, or 9650SE), a global view of the environment also includes summary information about detected enclosures. www.3ware.com 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103

Shell Object Commands
www.3ware.com
25
Example:
//localhost> focus /c0/u0
//localhost/c0/u0>
//localhost/c0/u0> focus..
//localhost/c0>
//localhost> focus u0
//localhost/c0/u0>
//localhost/c0> focus /
//localhost>
The focus command is available by default. You can disable focus by setting
TW_CLI_INPUT_STYLE to
old
. (See “Return Code” on page 96.) (This
does not apply to Mac OS X.)
show
This command shows a general summary of all detected controllers.
Note that the device drivers for the appropriate operating system should be
loaded for the list to show all controllers. The intention is to provide a global
view of the environment.
Example:
Typical output of the Show command looks like the following:
//localhost> show
Ctl
Model
Ports
Drives
Units
NotOpt
RRate
VRate
BBU
-----------------------------------------------------------------------
c0
9590SE-4ME
4
4
1
0
2
5
-
The output above indicates that Controller 0 is a 9590SE model with 4 Ports,
with 4 Drives detected (attached), total of 1 Unit, with no units in a NotOpt
(Not Optimal) state, RRate (Rebuild Rate) of 2, VRate (Verify Rate) of 5,
BBU of '-' (Not Applicable). Not Optimal refers to any state except OK and
VERIFYING. Other states include VERIFY-PAUSED, INITIALIZING, INIT-
PAUSED, REBUILDING, REBUILD-PAUSED, DEGRADED,
MIGRATING, MIGRATE-PAUSED, RECOVERY, INOPERABLE, and
UNKNOWN. RRate also applies to initializing, migrating, and recovery
background tasks. (Definitions of the unit statuses are available in the
3ware
Serial ATA RAID Controller User Guide
.)
If you have a system with an enclosure unit, such as the 3ware Sidecar, that
includes support for an EPCT (Enclosure Port Configuration Table),
applicable firmware and software, and an appropriate controller (9550SX,
9590SE, or 9650SE), a global view of the environment also includes
summary information about detected enclosures.