3Ware 9650SE-2LPB-10 CLI Guide - Page 93

Enclosure Object Commands, /ex show, e0/slot0, Enclosure, Temperature, Sensor

Page 93 highlights

Enclosure Object Commands Enclosure Object Commands Enclosure object commands provide information and perform actions related to a specific enclosure, such as /e0 and its elements, such as /e0/slot0. Enclosure object elements include slot, fan, and temperature sensor elements. These commands are supported on the 9550SX, 9590SE, and 9650SE controllers, when an appropriate enclosure is used. The enclosure must use an integrated AMCC/3ware CCU (chassis control unit), such as the 3ware Sidecar, or a chassis from a third-party vendor. (Check the 3ware web site for a list of chassis vendors that support enclosure services, as they become available.) If you purchased an enclosure directly from a third-party vendor, the appropriate EPCT (Enclosure Port Configuration Table) must have been downloaded to the controller in order to take advantage of these commands. If you have a 3ware Sidecar Kit, the required EPCT file is already installed. Note. Not all enclosure features may be available on enclosures that use an integrated AMCC/3ware CCU. Syntax /ex show (9550SX, 9590SE, 9650SE only) /ex show attribute [attribute ...] where attributes are: controllers|slots|fans|temp /ex show all (9550SX, 9590SE, 9650SE only) /ex/slotx show (9550SX, 9590SE, 9650SE only) /ex/slotx show identify (9550SX, 9590SE, 9650SE only) /ex/slotx set identify=on|off (9550SX, 9590SE, 9650SE only) /ex/fanx show /ex/tempx show (9550SX, 9590SE, 9650SE only) (9550SX, 9590SE, 9650SE only) /ex show This command shows summary information on the specified enclosure /ex. This report consists of four parts; the Enclosure summary listing the present elements, a Fan summary section listing of all present fans, a Temperature Sensor summary section listing of all present temperature sensors and a Slot summary section listing of slots and associated information for the specified enclosure. www.3ware.com 87

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103

Enclosure Object Commands
www.3ware.com
87
Enclosure Object Commands
Enclosure object commands provide information and perform actions related
to a specific enclosure, such as
/e0
and its elements, such as
/e0/slot0
.
Enclosure object elements include slot, fan, and temperature sensor elements.
These commands are supported on the 9550SX, 9590SE, and 9650SE
controllers, when an appropriate enclosure is used. The enclosure must use an
integrated AMCC/3ware CCU (chassis control unit), such as the 3ware
Sidecar, or a chassis from a third-party vendor. (Check the 3ware web site for
a list of chassis vendors that support enclosure services, as they become
available.) If you purchased an enclosure directly from a third-party vendor,
the appropriate EPCT (Enclosure Port Configuration Table) must have been
downloaded to the controller in order to take advantage of these commands.
If you have a 3ware Sidecar Kit, the required EPCT file is already installed.
Syntax
/ex show
(9550SX, 9590SE, 9650SE only)
/ex show attribute [attribute ...] where attributes are:
controllers|slots|fans|temp
/ex show all
(9550SX, 9590SE, 9650SE only)
/ex/slotx show
(9550SX, 9590SE, 9650SE only)
/ex/slotx show identify
(9550SX, 9590SE, 9650SE only)
/ex/slotx set identify=on|off
(9550SX, 9590SE, 9650SE only)
/ex/fanx show
(9550SX, 9590SE, 9650SE only)
/ex/tempx show
(9550SX, 9590SE, 9650SE only)
/e
x
show
This command shows summary information on the specified enclosure
/ex
.
This report consists of four parts; the
Enclosure
summary listing the present
elements, a
Fan
summary section listing of all present fans, a
Temperature
Sensor
summary section listing of all present temperature sensors and a
Slot
summary section listing of slots and associated information for the specified
enclosure.
Note.
Not all enclosure features may be available on enclosures that use an
integrated AMCC/3ware CCU.