3Ware 9650SE-2LPB-10 CLI Guide - Page 60

/cx set verify=enable|disable|1..5, /cx set selftest=enable|disable [task=UDMA|SMART]

Page 60 highlights

Chapter 2. CLI Syntax Reference The priority of rebuild versus I/O operations is specified with 1..5, where 1 is more resources and 5 the least. Setting the value to 1 gives maximum processing time to rebuilds rather than I/O. Setting the value to 5 gives maximum processing time to I/O rather than rebuilds. Enabling and disabling rebuild schedules is only for 9000 models, however the rebuild rate (1..5) applies to all controllers. 7000- and 8000-series controllers have only one setting for Task Rate; it applies to both rebuild and verify rates. This rate is not persistent following a reboot for 7000- and 8000-series controllers. /cx set verify=enable|disable|1..5 This command enables or disables all verify background task slots on controller /cx and (when enabled) sets the priority of verification versus I/O operations. When enabled, verify tasks will only be run during the time slots scheduled for verifies. If a verify is taking place when the schedule is enabled, it will be paused until the next scheduled time. The priority of verify versus I/O operations is specified with 1..5, where 1 is more resources and 5 the least. Setting this value to 1 implies fastest verify, and 5 implies fastest I/O. Enabling and disabling verify schedules is only for 9000 models, however the verify rate (1..5) applies to all controllers. Note: When enabling the verify schedule you must also remember to enable the autoverify setting for the units to be verified. For more information see "/cx/ux set autoverify=on|off" on page 68. /cx set selftest=enable|disable [task=UDMA|SMART] This command enables or disables all selftest tasks or a particular selftest_task (UDMA or SMART). Enabling and disabling selftest is only for 9000 models. 7/8000 models have the same internal schedule, but it is not viewable or changeable. Example: //localhost> /c0 selftest=enable task=UDMA enables UDMA selftest on controller c0. 54 3ware Serial ATA RAID Controller CLI Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103

Chapter 2. CLI Syntax Reference
54
3ware Serial ATA RAID Controller CLI Guide
The priority of rebuild versus I/O operations is specified with
1..5
, where 1 is
more resources and 5 the least. Setting the value to 1 gives maximum
processing time to rebuilds rather than I/O. Setting the value to 5 gives
maximum processing time to I/O rather than rebuilds.
Enabling and disabling rebuild schedules is only for 9000 models, however
the rebuild rate (
1..5
) applies to all controllers.
7000- and 8000-series controllers have only one setting for Task Rate; it
applies to both rebuild and verify rates. This rate is not persistent following a
reboot for 7000- and 8000-series controllers.
/c
x
set verify=enable|disable|1..5
This command enables or disables all verify background task slots on
controller
/c
x
and (when enabled) sets the priority of verification versus I/O
operations. When enabled, verify tasks will only be run during the time slots
scheduled for verifies. If a verify is taking place when the schedule is enabled,
it will be paused until the next scheduled time.
The priority of verify versus I/O operations is specified with
1..5,
where 1 is
more resources and 5 the least. Setting this value to 1 implies fastest verify,
and 5 implies fastest I/O.
Enabling and disabling verify schedules is only for 9000 models, however the
verify rate (
1..5
) applies to all controllers.
/c
x
set selftest=enable|disable
[task=UDMA|SMART]
This command enables or disables all selftest tasks or a particular
selftest_task (UDMA or SMART).
Enabling and disabling selftest is only for 9000 models. 7/8000 models have
the same internal schedule, but it is not viewable or changeable.
Example:
//localhost> /c0 selftest=enable task=UDMA
enables UDMA selftest on controller c0.
Note:
When enabling the verify schedule you must also remember to enable the
autoverify setting for the units to be verified. For more information see
“/cx/ux set autoverify=on|off” on page 68.