Indicators, Orange, Green, Flashing

Page 96 highlights

Indicators Light Status & Description POWE R TEMP LAMP Power events Orange Off Green Flashing Off Green Off Orange Flashing Off Lamp events Orange Flashing Off Off Off Thermal events Off Red Off Red Off Red Red Red Red Red Red Red Green Red Green Red Off Stand-by mode Off Powering up Off Normal operation 1. The projector needs 90 seconds to cool down as it was abnormally shut down without the normal cooling down process. Or 2. The projector needs to cool for 90 seconds after the Off power is turned off. Or 3. The projector has shutdown automatically. If you try to re-start the projector, it will shutdown again. Please contact your dealer for assistance. The projector has shutdown automatically. If you try to reRed start the projector, it will shutdown again. Please contact your dealer for assistance. Red 1. 2. The projector needs 90 seconds to cool down. Or Please contact your dealer for assistance. Off Red Green Red The projector has shutdown automatically. If you try to restart the projector, it will shutdown again. Please contact Green your dealer for assistance. Orange Red Green 96 Maintenance

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

Maintenance
96
Indicators
Light
Status & Description
POWE
R
TEMP
LAMP
Power events
Orange
Off
Off
Stand-by mode
Green
Flashing
Off
Off
Powering up
Green
Off
Off
Normal operation
Orange
Flashing
Off
Off
1.
The projector needs 90 seconds to cool down as it
was abnormally shut down without the normal cooling
down process.
Or
2.
The projector needs to cool for 90 seconds after the
power is turned off.
Or
3.
The projector has shutdown automatically. If you try
to re-start the projector, it will shutdown again. Please
contact your dealer for assistance.
Lamp events
Orange
Flashing
Off
Red
The projector has shutdown automatically. If you try to re-
start the projector, it will shutdown again. Please contact
your dealer for assistance.
Off
Off
Red
1.
The projector needs 90 seconds to cool down.
Or
2.
Please contact your dealer for assistance.
Thermal events
Off
Red
Off
The projector has shutdown automatically. If you try to re-
start the projector, it will shutdown again. Please contact
your dealer for assistance.
Off
Red
Red
Off
Red
Green
Red
Red
Red
Red
Red
Green
Red
Red
Orange
Green
Red
Red
Green
Red
Green