Attaching the Roller Unit and Separation, Attach the roller unit.

Page 37 highlights

4 Grasp both sides of the separation pad with your fingers, and remove the separation pad. Attaching the Roller Unit and Separation Pad 1 Attach the separation pad. Press the separation pad down gently until it snaps into place, and make sure it is securely attached. 5 Use a cloth dampened with water and thoroughly wrung out to wipe the rollers and separation pad clean. 2 Attach the roller unit. Insert the shaft pin of the roller unit into the notch on the scanner (A), and attach the lock lever vertically (B). A B 33