Compaq 1592DMT Compaq Armada 1500 Family of Personal Computers Maintenance and - Page 205

Command, Description, Ext. Result Code, Dial Tone Detect

Page 205 highlights

Addendum to Compaq Armada 1500 Maintenance and Service Guide Table C-1, Modem Commands, Continued Command Xn Extended Result Codes Dial Tone Detect Busy Tone Detect Yn Zn Description Result Code Selection and Call Progress Monitoring. Xn enables tone detection options used in the dialing process. As these functions are chosen, the modem chip set's result codes are also affected. Therefore, this command is frequently used to control the modem chip set's responses. The primary function of this control is to control the modem chip set's call response capabilities. Ext. Result Code Dial Tone Detect Busy Tone Detect X0: Disable Disable Disable X1: Enable Disable Disable X2: Enable Enable Disable X3: Enable Disable Enable X4: Enable Enable Enable (Default) X5: Enable Enable Enable X6: Enable Enable Enable X7: Disable Enable Enable Disabled: Displays only the basic result codes OK, CONNECT, RING, NO CARRIER, and ERROR Enabled: Displays basic result codes, along with the connect message and the modem's date, rate, and an indication of the modem's error correction and data compression operation Disabled: The modem dials a call regardless of whether it detects a dial tone. The period of time the modem waits before dialing is specified in register S6. Enabled: The modem dials only upon detection of a dial tone, and disconnects the call if the dial tone is not detected within 10 seconds. Disabled: The modem ignores any busy tones it receives. Enabled: The modem monitors for busy tones. Long Space Disconnect. Long space disconnect is always disabled. 0: Disable long space disconnect (default). 1: Enable long space disconnect. NOT SUPPORTED Recall Stored Profile. Zn instructs the modem chip set to go on-hook and restore the profile saved by the last &W command. Either Z0 or Z1 restores the same single profile. 0: Recall user profile. 1: Recall user profile. 22 Addendum 255318-001 to Guide 284820-001

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Addendum to Compaq Armada 1500
Maintenance and Service Guide
22
Addendum 255318-001 to Guide 284820-001
Table C-1, Modem Commands,
Continued
Command
Description
Xn
Result Code Selection and Call Progress Monitoring.
Xn enables tone detection options used
in the dialing process.
As these functions are chosen, the modem chip set’s result codes are
also affected.
Therefore, this command is frequently used to control the modem chip set's
responses.
The primary function of this control is to control the modem chip set’s call
response capabilities.
Ext. Result Code
Dial Tone Detect
Busy Tone Detect
X0:
Disable
Disable
Disable
X1:
Enable
Disable
Disable
X2:
Enable
Enable
Disable
X3:
Enable
Disable
Enable
X4:
Enable
Enable
Enable (Default)
X5:
Enable
Enable
Enable
X6:
Enable
Enable
Enable
X7:
Disable
Enable
Enable
Extended Result Codes
Disabled: Displays only the basic result codes OK, CONNECT,
RING,
NO CARRIER, and
ERROR
Enabled:
Displays basic result codes, along with the connect message and the modem’s
date, rate, and an indication of the modem’s error correction and data compression operation
Dial Tone Detect
Disabled: The modem dials a call regardless of whether it detects a dial tone.
The period of
time the modem waits before dialing is specified in register S6.
Enabled:
The modem dials only upon detection of a dial tone, and disconnects the call if the
dial tone is not detected within 10 seconds.
Busy Tone Detect
Disabled:
The modem ignores any busy tones it receives.
Enabled:
The modem monitors for busy tones.
Yn
Long Space Disconnect.
Long space disconnect is always disabled.
0:
Disable long space disconnect (default).
1:
Enable long space disconnect.
NOT SUPPORTED
Zn
Recall Stored Profile.
Zn instructs the modem chip set to go on-hook and restore the profile
saved by the last &W command.
Either Z0 or Z1 restores the same single profile.
0:
Recall user profile.
1:
Recall user profile.