D-Link DSN-656 User Manual - Page 144

PD RPS started F2F

Page 144 highlights

D-Link Document - User Manual WARNING INFO WARNING WARNING INFO INFO ERROR ERROR DEBUG WARNING INFO INFO WARNING INFO WARNING INFO WARNING WARNING WARNING WARNING INFO WARNING WARNING WARNING WARNING INFO INFO INFO INFO INFO INFO JBOD SMART fail JBOD CTR inserted JBOD CTR iremoved JBOD degraded PD dedicated spare PD global spare Config read fail Config write fail PD read error PD write error PD scrub started PD scrub completed PS fail PS normal FAN fail FAN normal Volt warn OV Volt warn UV Volt crit OV Volt crit UV Volt recovery Therm warn OT Therm warn UT Therm fail OT Therm fail UT Therm recovery JBOD HDD path NG PD RPS started L2F PD RPS started F2L PD RPS started F2F PD RPS finished L2F JBOD disk : Failure to get S.M.A.R.T information Controller() of JBOD is inserted into system Controller() of JBOD is removed from system JBOD is in degraded mode. Assign JBOD PD to be the dedicated spare disk of RG . Assign JBOD PD to Global Spare Disks. Config read error occurred at LBA - of JBOD PD . Config write error occurred at LBA - of JBOD PD . Read error occurred at LBA - of JBOD PD . Write error occurred at LBA - of JBOD PD . JBOD PD starts disk scrubbing process. JBOD PD completed disk scrubbing process. Power Supply of in JBOD is FAIL Power Supply of in JBOD is NORMAL Cooling fan of in JBOD is FAIL Cooling fan of in JBOD is NORMAL Voltage of read as in JBOD is WARN OVER Voltage of read as in JBOD is WARN UNDER Voltage of read as in JBOD is CRIT OVER Voltage of read as in JBOD is CRIT UNDER Voltage of in JBOD is NORMAL Temperature of read as in JBOD is OT WARNING Temperature of read as in JBOD is UT WARNING Temperature of read as in JBOD is OT FAILURE Temperature of read as in JBOD is UT FAILURE Temperature of in JBOD is NORMAL Path redundancy to JBOD PD is lost Assign JBOD PD to replace PD . Assign PD to replace JBOD PD . Assign JBOD PD to replace JBOD PD . PD is replaced by JBOD PD . Copyright@2014 D-Link System, Inc. All Rights Reserved. 144

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155

D-Link Document – User Manual
WARNING
JBOD SMART fail
JBOD <name> disk <slot>: Failure to get S.M.A.R.T
information
INFO
JBOD CTR inserted
Controller(<number>) of JBOD <name> is inserted into
system
WARNING
JBOD CTR
iremoved
Controller(<number>) of JBOD <name> is removed from
system
WARNING
JBOD degraded
JBOD <name> is in degraded mode.
INFO
PD dedicated
spare
Assign JBOD <name> PD <slot> to be the dedicated spare
disk of RG <name>.
INFO
PD global spare
Assign JBOD <name> PD <slot> to Global Spare Disks.
ERROR
Config read fail
Config read error occurred at LBA <address>-<address> of
JBOD <name> PD <slot>.
ERROR
Config write fail
Config write error occurred at LBA <address>-<address> of
JBOD <name> PD <slot>.
DEBUG
PD read error
Read error occurred at LBA <address>-<address> of JBOD
<name> PD <slot>.
WARNING
PD write error
Write error occurred at LBA <address>-<address> of JBOD
<name> PD <slot>.
INFO
PD scrub started
JBOD <name> PD <slot> starts disk scrubbing process.
INFO
PD scrub
completed
JBOD <name> PD <slot> completed disk scrubbing
process.
WARNING
PS fail
Power Supply of <string> in JBOD <name> is FAIL
INFO
PS normal
Power Supply of <string> in JBOD <name> is NORMAL
WARNING
FAN fail
Cooling fan of <string> in JBOD <name> is FAIL
INFO
FAN normal
Cooling fan of <string> in JBOD <name> is NORMAL
WARNING
Volt warn OV
Voltage of <string> read as <string> in JBOD <name> is
WARN OVER
WARNING
Volt warn UV
Voltage of <string> read as <string> in JBOD <name> is
WARN UNDER
WARNING
Volt crit OV
Voltage of <string> read as <string> in JBOD <name> is
CRIT OVER
WARNING
Volt crit UV
Voltage of <item> read as <string> in JBOD <name> is CRIT
UNDER
INFO
Volt recovery
Voltage of <string> in JBOD <string> is NORMAL
WARNING
Therm warn OT
Temperature of <string> read as <string> in JBOD <name>
is OT WARNING
WARNING
Therm warn UT
Temperature of <string> read as <string> in JBOD <name>
is UT WARNING
WARNING
Therm fail OT
Temperature of <string> read as <string> in JBOD <name>
is OT FAILURE
WARNING
Therm fail UT
Temperature of <string> read as <string> in JBOD <name>
is UT FAILURE
INFO
Therm recovery
Temperature of <string> in JBOD <name> is NORMAL
INFO
JBOD HDD path
NG
Path redundancy to JBOD <name> PD <number> is lost
INFO
PD RPS started L2F
Assign JBOD <name> PD <slot> to replace PD <slot>.
INFO
PD RPS started F2L
Assign PD <slot> to replace JBOD <name> PD <slot>.
INFO
PD RPS started F2F
Assign JBOD <name> PD <slot> to replace JBOD <name>
PD <slot>.
INFO
PD RPS finished
L2F
PD <slot> is replaced by JBOD <name> PD <slot>.
144