D-Link DSN-656 User Manual - Page 78

Enclosure Management, S.M.A.R.T.

Page 78 highlights

D-Link Document - User Manual  Connected: The replication task pair is connected.  Reconnecting: The source is reconnecting to the target. The options available on this tab are:  Create: Create a replication task.  Rebuild: Rebuild the replication task which is changed from a cloning job.  Replication Options: Set replication options.  Shaping Setting Configuration: Set task shaping configurations. The following options are available after creating a replication task in the "Task" table Start: Start the replication task Stop: Stop the replication task Set Task Shaping: Set task shaping group Add Path: Add multi path for the replication task Schedule: Set the replication task by schedule Delete: Delete the replication task. The following options are available after creating a replication task in the "Task Path" table Add Connection: Add a connection to the replication task Delete Connection: Delete the connection for the replication task Delete: Delete a multi path of the replication task. Described in detail in chapter 5. Enclosure Management The Enclosure Management menu option is for accessing the Hardware Monitor, UPS, SES, and S.M.A.R.T. option tabs. For the enclosure management, there are many sensors for different purposes, such as temperature sensors, voltage sensors, hard disk status, fan sensors, power sensors, and LED status. Due to the different hardware characteristics among these sensors, they have different polling intervals. Below are the details of the polling time intervals:  Temperature sensors: 1 minute.  Voltage sensors: 1 minute.  Hard disk sensors: 10 minutes. Copyright@2014 D-Link System, Inc. All Rights Reserved. 78

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155

D-Link Document – User Manual
Connected: The replication task pair is connected.
Reconnecting: The source is reconnecting to the target.
The options available on this tab are:
Create:
Create a replication task.
Rebuild:
Rebuild the replication task which is changed from a cloning job.
Replication Options:
Set replication options.
Shaping Setting Configuration:
Set task shaping configurations.
The following options are available after creating a replication task in the “Task” table:
-> Start:
Start the replication task.
-> Stop:
Stop the replication task.
-> Set Task Shaping:
Set task shaping group.
-> Add Path:
Add multi path for the replication task.
-> Schedule:
Set the replication task by schedule.
-> Delete:
Delete the replication task.
The following options are available after creating a replication task in the “Task Path” table:
-> Add Connection:
Add a connection to the replication task.
-> Delete Connection:
Delete the connection for the replication task.
-> Delete:
Delete a multi path of the replication task.
Described in detail in chapter 5.
Enclosure Management
The
Enclosure Management
menu option is for accessing the
Hardware Monitor
,
UPS
,
SES
, and
S.M.A.R.T.
option tabs.
For the enclosure management, there are many sensors for different purposes, such as
temperature sensors, voltage sensors, hard disk status, fan sensors, power sensors, and LED
status. Due to the different hardware characteristics among these sensors, they have different
polling intervals. Below are the details of the polling time intervals:
Temperature sensors: 1 minute.
Voltage sensors: 1 minute.
Hard disk sensors: 10 minutes.
78
Copyright@2014 D-Link System, Inc. All Rights Reserved.