the switch to the appropriate device. Ensure each fibre- optic

Page 27 highlights

Installing the DS-16B2 Switch 12. Align the slots on the bezel with the bezel supports and the ball studs. Push the bezel until it snaps into place, as shown in Figure 22. Figure 22 EMC2055 Installing the Bezel 13. Plug the other end of the ac cords into available receptacles on the PDU. 14. Attach the fibre-optic cables to the switch and run the cables from the switch to the appropriate device. Ensure each fibre- optic cable has a minimum bend radius of 2 inches. 15. Secure the cables with the Velcro strips attached to the rack/cabinet. EMC Departmental Switch DS-16B2 Installation Guide 27