Epson TM U295 Operation Guide - Page 66
ESC u, DLE EOT, When Auto Status Back ASB is enabled using
View all Epson TM U295 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 66 highlights
• The 1 byte status data is transmitted after printing and paper feed operation completely stop (transmit timing differs from ESC u, GS I). • This command is executed when the data is processed in the receive buffer. Therefore, there may be a time lag between receiving the command and transmitting the status, depending on the receive buffer status. • When Auto Status Back (ASB) is enabled using GS a, the status transmitted by ESC v and the ASB status must be differentiated. • The status to be transmitted is shown in the table below. Bit Off/On Hex Decimal Function Off 0 On 00 0 01 1 Slip is detected by BOF sensor. Slip is not detected by BOF sensor. Off 1 On 00 0 02 2 Slip is detected by TOF sensor. Slip is not detected by TOF sensor. Off 2 On 00 0 04 4 Undefined. Undefined. Off 3 On 00 0 08 8 Undefined. Undefined. 4 Off 00 0 Not used. Fixed to Off. Off 5 On 00 0 20 32 Undefined. Undefined. Off 6 On 00 0 40 64 Undefined. Undefined. 7 Off 00 0 Not used. Fixed to Off. [Reference] DLE EOT, GS a Paper Specifications ESC { n [Name] [Format] [Range] Turns on/off upside-down printing mode ASCII ESC { n Hex 1B 7B n Decimal 27 123 n 0 ≤ n ≤ 255 5-26 Commands