this command., The status types to be transmitted are shown below
View all Epson TM U295 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 73 highlights
• When Auto Status Back (ASB) is enabled using GS a, the status transmitted by GS r and the ASB status must be differentiated. • If the value of n is out of the specified range, the printer ignores this command. • The status types to be transmitted are shown below: Paper sensor status (n = 1, 49): Bit Off/On Hex Decimal Status for ASB Off 0 On 00 0 01 1 Slip is detected by BOF sensor. Slip is not detected by BOF sensor. Off 1 On 00 0 02 2 Slip is detected by TOF sensor Slip is not detected by TOF sensor. Off 2 On 00 0 04 4 Undefined. Undefined. Off 3 On 00 0 08 8 Undefined. Undefined. 4 Off 00 0 Not used. Fixed to Off. Off 5 On 00 0 20 32 Undefined. Undefined. Off 6 On 00 0 40 64 Undefined. Undefined. 7 Off 00 0 Not used. Fixed to Off. Drawer kick-out connector status (n = 2, 50): Bit Off/On Hex Decimal Status for ASB Off 0 On 00 0 01 1 Drawer kick-out connector pin 3 is LOW. Drawer kick-out connector pin 3 is HIGH. Off 1 On 00 0 02 2 Undefined. Undefined. Off 2 On 00 0 04 4 Undefined. Undefined. Off 3 On 00 0 08 8 Undefined. Undefined. Commands 5-33