Fluke 124 FE 123 & 124 Users Manual - Page 73

Dual Input Meter, Input A and Input B

Page 73 highlights

Dual Input Meter The accuracy of all measurements is within ± (% of reading + number of counts) from 18 °C to 28 °C. Add 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1 probe, add probe uncertainty +1%. More than one waveform period must be visible on the sceen. Input A and Input B DC Voltage (VDC) Ranges 500 mV, 5V, 50V, 500V, 1250V Accuracy 0.5% +5 counts) Normal Mode Rejection (SMR 60 dB @ 50 or 60 Hz ±1% Common Mode Rejection (CMRR)........>100 dB @ DC >60 dB @ 50, 60, or 400 Hz Full Scale Reading 5000 counts True RMS Voltages (VAC and VAC+DC) Ranges 500 mV, 5V, 50V, 500V, 1250V Accuracy for 5 to 100% of range DC coupled: DC to 60 Hz (VAC+DC 1% +10 counts) 1 Hz to 60 Hz (VAC 1% +10 counts) AC or DC coupled: 60 Hz to 20 kHz 2.5% +15 counts) 20 kHz to 1 MHz 5% +20 counts) 1 MHz to 5 MHz 10% +25 counts) 4 Specifications Dual Input Meter 5 MHz to 12.5 MHz 30% +25 counts) 5 MHz to 20 MHz (excl. test leads or probes) .......... ±(30% +25 counts) AC coupled with 1:1 (shielded) test leads 60 Hz (6 Hz with 10:1 probe 1.5% 50 Hz (5 Hz with 10:1 probe 2% 33 Hz (3.3 Hz with 10:1 probe 5% 10 Hz (1 Hz with 10:1 probe 30% DC Rejection (only VAC 50 dB Common Mode Rejection (CMRR) ....... >100 dB @ DC >60 dB @ 50, 60, or 400 Hz Full Scale Reading 5000 counts The reading is independent of any signal crest factor. Peak Modes Max peak, Min peak, or pk-to-pk Ranges 500 mV, 5V, 50V, 500V, 1250V Accuracy: Max peak or Min peak 5% of full scale Peak-to-Peak 10% of full scale Full Scale Reading 500 counts Frequency (Hz) Ranges 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz (Fluke 123) or 70MHz (Fluke 124) Frequency Range in Continuous Autoset 15 Hz (1 Hz) to 50 MHz 65

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86

Specifications
Dual Input Meter
4
65
Dual Input Meter
The accuracy of all measurements is within
±
(% of
reading + number of counts) from 18
°
C to 28
°
C.
Add 0.1x (specific accuracy) for each
°
C below 18
°
C or
above 28
°
C. For voltage measurements with 10:1 probe,
add probe uncertainty +1%. More than one waveform
period must be visible on the sceen.
Input A and Input B
DC Voltage (VDC)
Ranges
........................
500 mV, 5V, 50V, 500V, 1250V
Accuracy
..........................................
±
(0.5% +5 counts)
Normal Mode Rejection (SMR)
...........................
>60 dB
@ 50 or 60 Hz
±
1%
Common Mode Rejection (CMRR)
........
>100 dB @ DC
>60 dB @ 50, 60, or 400 Hz
Full Scale Reading
....................................
5000 counts
True RMS Voltages (VAC and VAC+DC)
Ranges
........................
500 mV, 5V, 50V, 500V, 1250V
Accuracy for 5 to 100% of range
DC coupled:
DC to 60 Hz (VAC+DC)
...............
±
(1% +10 counts)
1 Hz to 60 Hz (VAC)
....................
±
(1% +10 counts)
AC or DC coupled:
60 Hz to 20 kHz
........................
±
(2.5% +15 counts)
20 kHz to 1 MHz
..........................
±
(5% +20 counts)
1 MHz to 5 MHz
.........................
±
(10% +25 counts)
5 MHz to 12.5 MHz
...................
±
(30% +25 counts)
5 MHz to 20 MHz (excl. test leads or probes)
..........
±
(30% +25 counts)
AC coupled with 1:1 (shielded) test leads
60 Hz (6 Hz with 10:1 probe)
.........................
-1.5%
50 Hz (5 Hz with 10:1 probe)
............................
-2%
33 Hz (3.3 Hz with 10:1 probe)
.........................
-5%
10 Hz (1 Hz with 10:1 probe)
..........................
-30%
DC Rejection (only VAC)
...................................
>50 dB
Common Mode Rejection (CMRR)
.......
>100 dB @ DC
>60 dB @ 50, 60, or 400 Hz
Full Scale Reading
....................................
5000 counts
The reading is independent of any signal crest factor.
Peak
Modes
.........................
Max peak, Min peak, or pk-to-pk
Ranges
........................
500 mV, 5V, 50V, 500V, 1250V
Accuracy:
Max peak or Min peak
........................
5% of full scale
Peak-to-Peak
...................................
10% of full scale
Full Scale Reading
......................................
500 counts
Frequency (Hz)
Ranges
................
1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz,
100 kHz,1 MHz, 10 MHz, and 50 MHz (Fluke 123) or
70MHz (Fluke 124)
Frequency Range in Continuous Autoset
......................
15 Hz (1 Hz) to 50 MHz