Maintenance Information, 6.2.1 Maintenance requirements, BUFFER and READ BUFFER commands.
View all Fujitsu MAF3364LC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 110 highlights
(1) Interface (SCSI bus) test The operations of the SCSI bus and data buffer on the IDD are checked with the WRITE BUFFER and READ BUFFER commands. (2) Basic operation test The basic operations of the IDD are checked by executing self-diagnosis with the SEND DIAGNOSTIC command (see Subsection 6.1.1). (3) Random/sequential read test The positioning (seek) operation and read operation are tested in random access and sequential access modes with the READ, READ EXTENDED, or VERIFY command. (4) Write/read test By using a data block in the internal test space, the write/read test can be executed with an arbitrary pattern for a disk drive in which user data is stored. 6.2 Maintenance Information 6.2.1 Maintenance requirements (1) Preventive maintenance Preventive maintenance such as replacing air filters is not required. CAUTION Damage Do not open the DE in the field because it is completely sealed. (2) Service life The service life under suitable conditions and treatment is as follows. The service life is depending on the environment temperature. Therefore, the user must design the system cabinet so that the average DE surface temperature is as possible as low. • DE surface temperature: 45°C or less • DE surface temperature: 46°C to 50°C • DE surface temperature: 51°C to 55°C • DE surface temperature: 56°C and more 5 years 4 years 3 years strengthen cooling power so that DE surface temperature is 55°C or less. Even if the IDD is used intermittently, the longest service life is 5 years. C141-E064-03EN 6 - 5