Fujitsu MAF3364LC Manual/User Guide - Page 120
For LC/MC models, C141-E064-03EN, B - 3, Setting at factory shipment
View all Fujitsu MAF3364LC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 120 highlights
For LC/MC models Setting item Pins Setting contents 11 - 12 13 - 14 15 - 16 23 - 24 Motor start mode Open Started by turning the power supply on (*) Short Started by the START/STOP command Force Narrow Open Width of 16 bit bus (*) Short Width of 8 bit bus Force Single Ended Open Follows DIFFSNS signal level on SCSI bus (*) * Setting at factory shipment Short Single-Ended mode Note: See the description of Section 5.3 for details of the setting requirements and notes. C141-E064-03EN B - 3
C141-E064-03EN
B - 3
For LC/MC models
Setting item
Pins
Setting contents
11 - 12
13 - 14
15 - 16
23 - 24
Motor start mode
Open
Started by turning the power supply on (*)
Short
Started by the START/STOP command
Force Narrow
Open
Width of 16 bit bus (*)
Short
Width of 8 bit bus
Force Single Ended
Open
Follows DIFFSNS signal level on SCSI bus (*)
Short
Single-Ended mode
*
Setting at factory shipment
Note:
See the description of Section 5.3 for details of the setting requirements and notes.