Fujitsu MAF3364LC Manual/User Guide - Page 91

START/STOP UNIT command., Table 5.3, Motor start mode setting, Write protect setting CN2

Page 91 highlights

(2) Motor start mode Set how to control the starting of the IDD spindle motor according to Table 5.3. This setting only determines the operation mode when the power supply is turned on or the microcode is downloaded. In both modes, stopping or restarting the spindle motor can be controlled by specifying the START/STOP UNIT command. Table 5.3 Motor start mode setting Start timing of the spindle motor Starting of the motor is controlled with the START/STOP UNIT command. The motor is started immediately after the power supply is turned on or the microcode is downloaded. *1 Setting at factory shipment CN2 11-12 (LP/MP) Open Short (*1) CN2 11-12 (LC/MC) Short Open (*1) Refer to Chapter 3 of the SCSI Logical Interface Specifications for details of the START/STOP UNIT command. (3) Write protect When the write protect function is enabled, writing to the disk medium is disabled. Table 5.4 Write protect setting (CN2) Write protect Write operation is enabled. Write operation is disable. *1 Setting at factory shipment CN2 9-10 Open (*1) Short (4) Setting of the SCSI interface operation mode By establishing a short-circuit between the 15 and 16 CN2 setting terminals, the SCSI interface operation mode is forcibly set to the single-ended mode. When this setup terminal is open, the IDD automatically identifies the DIFFSNS signal level on the SCSI bus and the IDD SCSI interface operation mode is set to the operation mode. 5 - 8 C141-E064-03EN

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133

C141-E064-03EN
5 - 8
(2)
Motor start mode
Set how to control the starting of the IDD spindle motor according to Table 5.3.
This setting
only determines the operation mode when the power supply is turned on or the microcode is
downloaded.
In both modes, stopping or restarting the spindle motor can be controlled by
specifying the START/STOP UNIT command.
Table 5.3
Motor start mode setting
Start timing of the spindle motor
CN2 11-12
(LP/MP)
CN2 11-12
(LC/MC)
Starting of the motor is controlled with the START/STOP
UNIT command.
Open
Short
The motor is started immediately after the power supply is
turned on or the microcode is downloaded.
Short (*1)
Open (*1)
*1
Setting at factory shipment
Refer to Chapter 3 of the SCSI Logical Interface Specifications for details of the
START/STOP UNIT command.
(3)
Write protect
When the write protect function is enabled, writing to the disk medium is disabled.
Table 5.4
Write protect setting (CN2)
Write protect
CN2
9-10
Write operation is enabled.
Open (*1)
Write operation is disable.
Short
*1
Setting at factory shipment
(4)
Setting of the SCSI interface operation mode
By establishing a short-circuit between the 15 and 16 CN2 setting terminals, the SCSI
interface operation mode is forcibly set to the single-ended mode. When this setup terminal is
open, the IDD automatically identifies the DIFFSNS signal level on the SCSI bus and the IDD
SCSI interface operation mode is set to the operation mode.