5.3 Setting Terminals The user must set the following terminals and SCSI terminating resistor before installing the IDD in the system. • Setting terminal: CN2 Figures 5.2 shows the setting terminal position. Figures 5.3 shows the allocation and default settings. CAUTION Data loss 1. The user must not change the setting of terminals not described in this section. Do not change setting status set at factory shipment. 2. Do not change the setting of terminals except following setting pins during the power is turned on. • Write protect: CN2 9-10 3. To short the setting terminal, use the short plug attached when the device is shipped from the factory. CN1 CN2 1 pin Figure 5.2 IDD setting terminals position C141-E064-03EN 5 - 5
C141-E064-03EN
5 - 5
5.3
Setting Terminals
The user must set the following terminals and SCSI terminating resistor before installing the
IDD in the system.
•
Setting terminal:
CN2
Figures 5.2 shows the setting terminal position.
Figures 5.3 shows the allocation and default
settings.
CAUTION
Data loss
1.
The user must not change the setting of terminals not described in this
section.
Do not change setting status set at factory shipment.
2.
Do not change the setting of terminals except following setting pins
during the power is turned on.
•
Write protect:
CN2
9-10
3.
To short the setting terminal, use the short plug attached when the
device is shipped from the factory.
Figure 5.2
IDD setting terminals position
1 pin
CN2
CN1