Genie ScrewDrive Owner's Manual - Page 23

Safe-t-beam, Installation

Page 23 highlights

SAFE-T-BEAM ® INSTALLATION CAUTION Staples which are too tight can cut or pinch wires. Cut or pinched wires can cause the STB System to stop working. When using the insulated staples, make sure you fasten them only as tightly as needed to hold the wire snugly. • Make wire attachments at STBs. - Split and strip wire ends to be connected as shown Fig. 3-6. - Loosen terminal screws. - Insert wire under flat plate and tighten screw. It does not matter which wire, white or striped, goes on which terminal Fig. 3-7. • Make wire attachments at power head. - STBs are connected to terminals #3 and #4 on power head Fig. 3-8. It does not matter which wire, white or striped, goes on which terminal. 4. Check the following. • Ensure that no part of door or its hardware is in path between lenses of source and sensor. • Ensure that tops of lenses are between 5"-6" above the floor Fig. 3-9. The brackets are flexible, and can be adjusted slightly if needed. Fig. 3-6 Fig. 3-7 NOTE: Safe-T-Beam® alignment check will be performed following connection to electrical power (see page 26). DO NOT PLUG IN YET! (See Illustration on page 3 for a full view of Safe-T-Beam® location.) FOR HELP- GENIECOMPANY.COM 23 ≈ 1/2" ≈1-1/4" to 1-1/2" Fig. 3-8 top edge of lens between 5" - 6" above floor. Fig. 3-9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35

23
Make wire attachments at STBs.
Split and strip wire ends to be connected
as shown
Fig. 3-6
.
Loosen terminal screws.
Insert wire under flat plate and tighten screw.
It does not matter which wire, white or
striped, goes on which terminal
Fig. 3-7
.
Make wire attachments at power head.
STBs are connected to terminals #3 and
#4 on power head
Fig. 3-8
. It does not
matter which wire, white or striped, goes on
which terminal.
4.
Check the following
.
Ensure that no part of door or its hardware is
in path between lenses of
source
and
sensor
.
Ensure that tops of lenses are between 5"-6"
above the floor
Fig. 3-9
. The brackets are
flexible, and can be adjusted slightly if needed.
NOTE: Safe-T-Beam® alignment check will be
performed following connection to electrical
power (see page 26). DO NOT PLUG IN YET!
(See Illustration on page 3
for a full view of
Safe-T-Beam
®
location.)
Staples which are too tight can cut or pinch
wires. Cut or pinched wires can cause the STB
System to stop working. When using the
insulated staples, make sure you fasten them
only as tightly as needed to hold the wire snugly.
CAUTION
SAFE-T-BEAM
®
INSTALLATION
FOR HELP- GENIECOMPANY.COM
top edge of lens
between 5" - 6"
above floor.
Fig. 3-6
1-1/4" to 1-1/2"
1/2"
Fig. 3-7
Fig. 3-8
Fig. 3-9