From the advanced configuration select, Type the number of errors per minute at
View all HP 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 131 highlights
Configuring port fencing using the fwConfigure command A 10. Select apply threshold alarm changes by entering 16 at the Select choice = > prompt. 1 : change behavior type 11 : change threshold alarm level 2 : change behavior interval 12 : change changed alarm 3 : change threshold boundary level 13 : change below alarm 4 : change custom unit 14 : change above alarm 5 : change custom time base 15 : change inBetween alarm 6 : change custom low 16 : apply threshold alarm changes 7 : change custom high 17 : cancel threshold alarm changes 8 : change custom buffer 18 : return to previous page 9 : apply threshold boundary changes 10 : cancel threshold boundary changes Select choice => : (1..18) [18] 16 11. Change the number of errors per minute using the following substeps: a. From the advanced configuration section, select change custom high by entering 7 at the Select choice = > prompt. b. Type the number of errors per minute at the Enter high threshold = > prompt. 1 : change behavior type 11 : change threshold alarm level 2 : change behavior interval 12 : change changed alarm 3 : change threshold boundary level 13 : change below alarm 4 : change custom unit 14 : change above alarm 5 : change custom time base 15 : change inBetween alarm 6 : change custom low 16 : apply threshold alarm changes 7 : change custom high 17 : cancel threshold alarm changes 8 : change custom buffer 18 : return to previous page 9 : apply threshold boundary changes 10 : cancel threshold boundary changes Select choice => : (1..18) [18] 7 Enter high threshold => : (0..999999999) [500] 100 12. Change the Threshold boundary level to custom by entering 3, and then select custom by entering 2 at the Enter boundary level type = > prompt. 1: change behavior type 11 : change threshold alarm level 2 : change behavior interval 12 : change changed alarm 3 : change threshold boundary level 13 : change below alarm 4 : change custom unit 14 : change above alarm 5 : change custom time base 15 : change inBetween alarm 6 : change custom low 16 : apply threshold alarm changes 7 : change custom high 17 : cancel threshold alarm changes 8 : change custom buffer 18 : return to previous page 9 : apply threshold boundary changes 10 : cancel threshold boundary changes Select choice => : (1..18) [18] 3 1 : Default 2 : custom Enter boundary level type => : (1..2) [1] 2 Fabric Watch Administrator's Guide 111 53-1001770-01