- HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 1
HP Smart Array P800 Controller for Integrity Servers Installation Guide HP-UX 11i v2 and 11i v3; OpenVMS 8.3 HP Part Number: 5992-3804 Published: December 2007 Edition: 1 - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 2
Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice. The only warranties for HP products and services are - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 3
...6 1 HP-UX Installation...7 Installation Overview...7 Installation Prerequisites...7 Downloading Software...8 Installing Software...8 Installing the Controller Offline...8 Replacing a Smart Array P800 Controller Online 9 Connecting External Devices...10 Verifying and Updating Controller Firmware - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 4
Offline 30 Verifying the Enclosure Firmware 30 Downloading the Firmware Update, If Needed 31 Updating the Enclosure Firmware 31 Verifying the Firmware Update 32 HELP or ?...32 Verifying the Controller Installation...33 Configuring a Smart Array Series Controller as a Boot Device 33 Configuring - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 5
Array controller hardware and drivers on HP-UX and OpenVMS. There are also several appendixes containing supplemental information. Chapter 1 HP-UX Installation This chapter covers Smart Array P800 Controller installation for HP-UX, including hardware requirements, software requirements, firmware - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 6
information about the HP Smart Array Series Controller Family can be found at: http://docs.hp.com/en/netcom.html Other documents in this collection include: HP RAID Technology Overview HP Smart Array RAID Controllers Support Matrix RAID-01 (ciss) Mass Storage Driver Release Notes HP Encourages Your - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 7
on supported RAID levels, see the HP Smart Array P400 and P800 Controller for Integrity Servers Support Guide at: http://docs.hp.com/en/netcom.html 2. Check the installation prerequisites. See "Installation Prerequisites" (page 7). 3. Install the software. See "Downloading Software" (page - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 8
Versions for Smart Array SAS RAID Controllers Controller Smart Array P400 Smart Array P800 Operating System HP-UX 11i v2 HP-UX 11i v3 HP-UX 11i v2 HP-UX 11i v3 Minimum Required Version B.11.23.0612 B.11.31.0709 B.11.23.0712 B.11.31.0712 For information about the supported server models and HP-UX - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 9
contact with hazardous energy levels. 8. Power on the server. Replacing a Smart Array P800 Controller Online You can use Online Addition, Replacement, and Deletion (OL*) to replace the Smart Array Controller online in HP-UX systems that support OL*, without powering off and rebooting the system - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 10
the target PCIe slot also suspends individual drivers for the multiple hardware paths on the controller installed in that PCI slot. To replace a Smart Array P800 controller online, follow these steps: 1. Confirm that you have the minimum ciss driver version to support OL* on your system. See the HP - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 11
you boot the server. Firmware version requirements are found in the HP Smart Array RAID Controllers Support Matrix at: http://docs.hp.com/en/netcom.html WARNING! HP Smart Array P800 Controllers have specific adapter firmware version requirements for use in HP Integrity servers. Follow the steps - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 12
the Firmware Update To locate and download firmware for the Smart Array P800 Controller, follow these steps: 1. Go to the Business Support Center, at: http://www.hp.com/go/bizsupport 2. Search for "Smart Array P800". 3. In the "Narrow search using only" section, click Drivers and software. 4. Locate - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 13
52:0:0 INCPTR.PAK Replace INCPTR.PAK with the name of your firmware file. For example: fs0:\EFI\TOOLS> saupdate update 0:52:0:0 INCPTR.PAK Smart Array Offline Firmware Update Utility Version 2.06.10.03 (C) Copyright 2006 Hewlett-Packard Development Company, L.P Updating controller in Seg: 0, Bus - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 14
See "Verifying the Controller Firmware" (page 11). For example: fs0:\EFI\TOOLS> saupdate list Smart Array Offline Firmware Update Utility Version 2.06.10.03 (C) Copyright 2006 Hewlett-Packard Development Company, L.P Seg Bus Dev Func Description Version 0 52 0 0 HP Smart Array P400 2.08 - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 15
Smart Array controllers along with the active firmware versions. For example: fs0:\EFI\TOOLS> saupdate list Smart Array Offline Firmware Update Utility Version 2.07.09.02 (C) Copyright 2006 Hewlett-Packard Development Company, L.P. Seg Bus Dev Func 0 8 0 0 Description HP Smart Array P800 - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 16
associated fs number (for example, fs0) under EFI Shell prompt. e. If the EFI utility and firmware image files HP\TOOLS\IO_CARDS\SmartArray • To run saupdate from the EFI partition: a. Download the Smart Array EFI update utility saupdate.efi and copy it to the EFI partition. b. Download the firmware - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 17
For HP-UX 11i v2: RAID-01 B.11.23.0706 RAID SA; Supptd HW=A7143A/A9890A/A9891A The version string that appears indicates the version of the RAID-01 bundle installed on your server. 2. Enter the ioscan -kfnd ciss command: # ioscan -kfnd ciss If the Smart Array Controller software is installed - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 18
manpages are explained in the HP Smart Array P400 and P800 Controller for Integrity Servers Support Guide at: http://docs.hp.com/en/netcom.html You must log in as a superuser to run the sautil command. Before running the sautil command to confirm or update physical disk firmware, you must know the - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 19
HP Device Product ID DG036A8B5B Device Serial Number B2G2P55001SF0519 Device Firmware Version HPD4 ---- SAS/SATA DEVICE 1I:1:11:0x500000e01115c352 [DISK Connector Location internal Connector 1I Enclosure 1 Bay 11 WWID 0x500000e01115c352 Device Type DISK Confirming and Updating Physical - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 20
GB Device Status OK Device Vendor ID HP Device Product ID DG036A8B53 Device Serial Number 3LC03L7Z0000854051PK Device Firmware Version HPD4 ---- SAS/SATA DEVICE 1I:1:9:0x5000c5000030b0c5 [DISK Connector Location internal Connector 1I Enclosure 1 Bay 9 WWID 0x5000c5000030b0c5 Device Type - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 21
page 22). For more information, see the HP Smart Array P400 and P800 Controller for Integrity Servers Support Guide at: http://docs.hp.com/en/netcom.html Planning to Install HP-UX on a Logical Drive On each Smart Array Controller, you can set up any number of its logical drives as boot devices. For - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 22
you have trouble accessing RAID boot data, only limited troubleshooting tools are available. HP recommends booting from an alternative boot media and using STM and sautil online tools. For more information, see the HP Smart Array P400 and P800 Controller for Integrity Servers Support Guide at: http - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 23
screen displays a list of available (unconfigured) physical drives and the valid RAID options for the system. 2. Use the arrow keys, space bar, HP Smart Array P400 and P800 Controller for Integrity Servers Support Guide at: http://docs.hp.com/en/netcom.html Configuring a Smart Array Series Controller - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 24
24 - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 25
are supported by the Controller. For information about the supported server models and OpenVMS versions, see the HP Smart Array RAID Controllers Support Matrix at: http://docs.hp.com/en/netcom.html 2. Read the driver release notes for your OpenVMS version to check for any known problems, required - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 26
for updated drivers and patches, follow these steps: • Go to the IT Resource Center website: http://itrc.hp.com/ • Search for "Smart Array". Installing Software To install Smart Array P800 driver software, follow the procedure in the download package. Installing the Controller CAUTION: Electronic - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 27
to boot the server. Firmware version requirements are found in the HP Smart Array RAID Controllers Support Matrix at: http://docs.hp.com/en/netcom.html WARNING! The HP Smart Array P800 Controller has specific adapter firmware version requirements for use in HP Integrity servers. Follow the steps - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 28
Firmware Update, If Needed To locate and download firmware for the Smart Array P800 Controller, follow these steps: 1. Go to the Business Support Center, at: http://www.hp.com/go/bizsupport 2. Search for "Smart Array P800". 3. In the "Narrow search using only:" section, click "Drivers and software - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 29
update the controller at segment 0, bus 52, device 0, function 0 from the example output above: fs0:\> saupdate UPDATE 0:52:0:0 INCPTR.PAK Replace INCPTR.PAK with the name of your firmware file. For example: fs0:\EFI\TOOLS> saupdate update 0:52:0:0 INCPTR.PAK Smart Array Offline Firmware Update - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 30
in which the file is located, for example: fs0:\>cd \EFI\HP\TOOLS\IO_CARDS\SmartArray • Run saupdate.efi using the using the fs0:\> saupdate.efi command. • Use saupdate LIST to display all detected Smart Array controllers along with the active firmware versions. For example: 30 OpenVMS Installation - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 31
with the update package to install the firmware update. Use saupdate from the EFI Shell to update the firmware image on the HP Smart Array controller. Follow one of these two procedures to run saupdate: • If you are using saupdate from the Offline Diagnostic CD: 1. Download the firmware and copy - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 32
see "Verifying the Controller Firmware" (page 11). For example: fs0:\EFI\TOOLS> saupdate list Smart Array Offline Firmware Update Utility Version 2.07.09.02 (C) Copyright 2006 Hewlett-Packard Development Company, L.P Seg Bus Dev Func 0 8 0 0 Description Version HP Smart Array P800 4.10 - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 33
data in cache. Battery: Battery is fully charged. 3. Use the MSA utility to configure and manage the Smart Array P800 controller. For more information about the MSA utility, see the OpenVMS Version 8.3-1H1 for Integrity Servers New Features and Release Notes at: http://h71000.www7.hp.com/doc - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 34
displays a list of all available (unconfigured) physical drives and the valid RAID options for the system. 2. Use the arrow keys, space bar, and cannot configure a single spare drive to be shared among more than one array. Each array must have its own spares. 3. Press Enter to accept the settings. - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 35
or more of the following grounding methods when handling or installing electrostatic-sensitive parts: • A wrist strap connected by a ground cord to a grounded floor mats. Use conductive field service tools. • A portable field service kit with a folding static-dissipating work mat. Handling Parts 35 - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 36
36 - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 37
HP Smart Array P400 and P800 controllers. Table B-1 Internal SAS Cable Kits Description Multi-lane A cable Host fan cable Target fan cable Multi-lane B cable Multi-lane 76-cm (30-in) cable Multi-lane 48-cm (19-in) cable Part Number 389647-B21 389650-B21 389653-B21 389659-B21 389662-B21 391330-B21 - HP 381513-B21 | HP Smart Array P800 Controller for Integrity Servers Installatio - Page 38
*5992-3804* Printed in the US
HP Smart Array P800 Controller for Integrity
Servers Installation Guide
HP-UX 11i v2 and 11i v3; OpenVMS 8.3