HP 381513-B21 HP Smart Array P800 Controller for Integrity Servers Installatio - Page 17

HELP or ?, Verifying the Installation, swlist, ioscan -kfnd ciss - firmware

Page 17 highlights

2. Use saupdate LIST to confirm that the correct firmware version is installed. See "Verifying the Controller Firmware" (page 11). For example: fs0:\EFI\TOOLS> saupdate list Smart Array Offline Firmware Update Utility Version 2.07.09.02 (C) Copyright 2006 Hewlett-Packard Development Company, L.P Seg Bus Dev Func 0 8 0 0 Description Version HP Smart Array P800 4.10 External Enclosures Connected : Index Description 2 MSA70 Version 2.06 HELP or ? Use HELP or ? to display usage text, program version number, and build date: Enter: saupdate HELP or saupdate ? Verifying the Installation After the system reboots, verify that the installation was successful by following these steps: 1. Enter the swlist command: # swlist If the Smart Array Controller is installed correctly, the generated output looks similar to the following examples: For HP-UX 11i v3: RAID-01 B.11.31.0709.01 RAID SA; Supptd HW=A7143A/A9890A/A9891A For HP-UX 11i v2: RAID-01 B.11.23.0706 RAID SA; Supptd HW=A7143A/A9890A/A9891A The version string that appears indicates the version of the RAID-01 bundle installed on your server. 2. Enter the ioscan -kfnd ciss command: # ioscan -kfnd ciss If the Smart Array Controller software is installed correctly, the generated output looks similar to this: # ioscan -kfnd ciss Class I H/W Path Driver S/W State H/W Type Description ext_bus 5 0/6/0/0/0/0/1/0/0/0 ciss CLAIMED INTERFACE PCIe SAS SmartArray P400 RAID Controller /dev/ciss5 If the software is not installed correctly, reinstall it using swinstall. See "Installing Software" (page 8). Verifying the Installation 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38

2.
Use
saupdate LIST
to confirm that the correct firmware version is installed. See
“Verifying
the Controller Firmware” (page 11)
.
For example:
fs0:\EFI\TOOLS>
saupdate list
************************************************************************
Smart Array Offline Firmware Update Utility
Version 2.07.09.02
(C) Copyright 2006 Hewlett-Packard Development Company, L.P.
************************************************************************
Seg
Bus
Dev
Func
Description
Version
0
8
0
0
HP Smart Array P800
4.10
External Enclosures Connected :
Index
Description
Version
2
MSA70
2.06
HELP or ?
Use HELP or ? to display usage text, program version number, and build date:
Enter:
saupdate HELP
or
saupdate ?
Verifying the Installation
After the system reboots, verify that the installation was successful by following these steps:
1.
Enter the
swlist
command:
#
swlist
If the Smart Array Controller is installed correctly, the generated output looks similar to the
following examples:
For HP-UX 11i v3:
RAID-01 B.11.31.0709.01
RAID SA; Supptd HW=A7143A/A9890A/A9891A
For HP-UX 11i v2:
RAID-01 B.11.23.0706
RAID SA; Supptd HW=A7143A/A9890A/A9891A
The version string that appears indicates the version of the RAID-01 bundle installed on
your server.
2.
Enter the
ioscan -kfnd ciss
command:
#
ioscan -kfnd ciss
If the Smart Array Controller software is installed correctly, the generated output looks
similar to this:
#
ioscan -kfnd ciss
Class
I
H/W Path
Driver
S/W State
H/W Type
Description
==========================================================================
ext_bus
5
0/6/0/0/0/0/1/0/0/0
ciss
CLAIMED
INTERFACE
PCIe SAS SmartArray P400 RAID Controller
/dev/ciss5
If the software is not installed correctly, reinstall it using
swinstall
. See
“Installing
Software” (page 8)
.
Verifying the Installation
17