HP 381513-B21 HP Smart Array P800 Controller for Integrity Servers Installatio - Page 30

HELP or ?, Error Messages, Verifying and Updating Enclosure Firmware Offline, Verifying the Enclosure Firmware

Page 30 highlights

HELP or ? Use HELP or ? to display usage text, program version number, and build date: Enter: saupdate HELP or saupdate ? Error Messages The following error messages may appear when using the saupdate utility: • When keyword LIST or UPDATE is misspelled or extra parameters are specified: Error: Syntax Error Usage: saupdate LIST or saupdate UPDATE [ | all ] • When the controller ID in the saupdate UPDATE command is not correct: No matching controller found • When a firmware file does not exist in the saupdate UPDATE command, the example shows: INCPTR.BIN does not exist. File INCPTR.BIN: Not Found • When an invalid firmware or corrupted file is specified in the saupdate UPDATE command, the example shows: INCPTR.BIN does not exist. File INCPTR.BIN: invalid or corrupted Verifying and Updating Enclosure Firmware Offline Follow the procedures in this section to check and update the firmware in an external enclosure. Verifying the Enclosure Firmware Use saupdate from the EFI Shell to update the firmware image on the controller. Follow one of these two procedures to run saupdate: • If you are using saupdate from the Offline Diagnostic CD: 1. Place the Offline Diagnostic CD containing saupdate.efi in the CD drive before booting the system. 2. Boot the system to the EFI Shell prompt. 3. Locate the cdrom entry in the list of mapped devices, and change to the device by typing its associated fs number (for example, fs0) under EFI Shell prompt. 4. If the EFI utility is not located in the root directory, move to the directory in which the file is located, for example: fs0:\>cd \EFI\HP\TOOLS\IO_CARDS\SmartArray • If you are not using the Offline Diagnostic CD: 1. Download the SA EFI update utility saupdate.efi and copy it to the EFI partition. 2. Boot the system to the EFI Shell and change directories to the EFI partition. 3. If the EFI utility is not located in the root directory, move to the directory in which the file is located, for example: fs0:\>cd \EFI\HP\TOOLS\IO_CARDS\SmartArray • Run saupdate.efi using the using the fs0:\> saupdate.efi command. • Use saupdate LIST to display all detected Smart Array controllers along with the active firmware versions. For example: 30 OpenVMS Installation

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38

HELP or ?
Use HELP or ? to display usage text, program version number, and build date:
Enter:
saupdate HELP
or
saupdate ?
Error Messages
The following error messages may appear when using the
saupdate
utility:
When keyword LIST or
UPDATE
is misspelled or extra parameters are specified:
Error: Syntax Error
Usage: saupdate LIST or saupdate UPDATE [ | all ]
When the controller ID in the
saupdate UPDATE
command is not correct:
No matching controller found
When a firmware file does not exist in the
saupdate UPDATE
command, the example
shows:
INCPTR.BIN does not exist
.
File INCPTR.BIN: Not Found
When an invalid firmware or corrupted file is specified in the
saupdate UPDATE
command,
the example shows:
INCPTR.BIN does not exist.
File INCPTR.BIN: invalid or corrupted
Verifying and Updating Enclosure Firmware Offline
Follow the procedures in this section to check and update the firmware in an external enclosure.
Verifying the Enclosure Firmware
Use
saupdate
from the EFI Shell to update the firmware image on the controller. Follow one
of these two procedures to run
saupdate
:
If you are using
saupdate
from the Offline Diagnostic CD:
1.
Place the Offline Diagnostic CD containing
saupdate.efi
in the CD drive before booting
the system.
2.
Boot the system to the EFI Shell prompt.
3.
Locate the
cdrom
entry in the list of mapped devices, and change to the device by typing
its associated fs number (for example,
fs0
) under EFI Shell prompt.
4.
If the EFI utility is not located in the root directory, move to the directory in which the file
is located, for example:
fs0:\>cd \EFI\HP\TOOLS\IO_CARDS\SmartArray
If you are not using the Offline Diagnostic CD:
1.
Download the SA EFI update utility
saupdate.efi
and copy it to the EFI partition.
2.
Boot the system to the EFI Shell and change directories to the EFI partition.
3.
If the EFI utility is not located in the root directory, move to the directory in which the file
is located, for example:
fs0:\>cd \EFI\HP\TOOLS\IO_CARDS\SmartArray
Run
saupdate.efi
using the using the
fs0:\> saupdate.efi
command.
Use
saupdate LIST
to display all detected Smart Array controllers along with the active
firmware versions. For example:
30
OpenVMS Installation